Literature DB >> 32045783

Longitudinal neural and vascular structural dynamics produced by chronic microelectrode implantation.

Cristin G Welle1, Yu-Rong Gao2, Meijun Ye3, Andrea Lozzi4, Adam Boretsky5, Erkinay Abliz3, Daniel X Hammer3.   

Abstract

Implanted microelectrode arrays sense local neuronal activity, signals which are used as control commands for brain computer interface (BCI) technology. Patients with tetraplegia have used BCI technology to achieve an extraordinary degree of interaction with their local environment. However, current microelectrode arrays for BCIs lose the ability to record high-quality neural signals in the months-to-years following implantation. Very little is known regarding the dynamic response of neurons and vasculature in the months following electrode array implantation, but loss of structural integrity near the electrode may contribute to the degradation of recording signals. Here, we use in-vivo dual-modality imaging to characterize neuronal and vasculature structures in the same animal for 3 months following electrode insertion. We find ongoing neuronal atrophy, but relative vascular stability, in close proximity to the electrode, along with evidence suggesting links between rare, abrupt hypoxic events and neuronal process atrophy.
Copyright © 2020. Published by Elsevier Ltd.

Entities:  

Keywords:  Chronic. (Min.5-Max. 8); Dendrite; Microelectrode; Neuroprosthetic; Vascular

Mesh:

Year:  2020        PMID: 32045783     DOI: 10.1016/j.biomaterials.2020.119831

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  4 in total

1.  Microelectrode implants, inflammatory response and long-lasting effects on NADPH diaphorase neurons in the rat frontal cortex.

Authors:  Joanilson S Guimaraes; Nelson Alessandretti M Lemos; Marco Aurelio M Freire; Antonio Pereira; Sidarta Ribeiro
Journal:  Exp Brain Res       Date:  2022-08-10       Impact factor: 2.064

2.  Imaging the stability of chronic electrical microstimulation using electrodes coated with PEDOT/CNT and iridium oxide.

Authors:  Xin Sally Zheng; Qianru Yang; Alberto Vazquez; Xinyan Tracy Cui
Journal:  iScience       Date:  2022-06-06

3.  Single-trial decoding of movement intentions using functional ultrasound neuroimaging.

Authors:  Sumner L Norman; David Maresca; Vassilios N Christopoulos; Whitney S Griggs; Charlie Demene; Mickael Tanter; Mikhail G Shapiro; Richard A Andersen
Journal:  Neuron       Date:  2021-03-22       Impact factor: 17.173

Review 4.  Engineering strategies towards overcoming bleeding and glial scar formation around neural probes.

Authors:  Elisabeth Otte; Andreas Vlachos; Maria Asplund
Journal:  Cell Tissue Res       Date:  2022-01-14       Impact factor: 5.249

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.