Literature DB >> 32045747

An improved method to estimate ultrasonic absorption in agar-based gel phantom using thermocouples and MR thermometry.

T Drakos1, M Giannakou1, G Menikou2, C Ioannides3, C Damianou1.   

Abstract

In this paper, a novel experimental set-up was developed that measures the absorption coefficient. The proposed system was evaluated in an agar-based gel phantom. The new experimental system provides accurate and fast measurement of the rate of temperature change within the phantom. The rate of temperature change was measured using thermocouple and was confirmed using MR thermometry. An ultrasonic transducer with a broad beam was used in order to reduce the conduction effect. The absorption coefficient of the agar-based phantom was 0.26 dB/cm-MHz using 4% agar, 30% evaporated milk and 4% silica. The absorption coefficient increased by increasing the volume of the evaporated milk, and agar. The absorption coefficient increased at low silica concentration (<4%) and then decreased at higher concentration of silica (>4%). By proper selection of evaporated milk, agar and silica concentration, it is possible to achieve similar coefficient like in soft tissues. Acoustic absorption measurement is considered as a difficult measurement in ultrasonics because obtaining the precise temperature change in the focus is challenging. Due to the quick and accurate placement of the thermocouple at the ultrasonic beam, it is possible with the proposed system to perform absorption measurement is less than one minute.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Absorption; Agar; MRI; Silica; Ultrasound

Year:  2020        PMID: 32045747     DOI: 10.1016/j.ultras.2020.106089

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

1.  Evaluation of ultrasonic scattering in agar-based phantoms using 3D printed scattering molds.

Authors:  Antria Filippou; Christakis Damianou
Journal:  J Ultrasound       Date:  2022-01-08

2.  Ultrasonic Attenuation of an Agar, Silicon Dioxide, and Evaporated Milk Gel Phantom.

Authors:  Theocharis Drakos; Anastasia Antoniou; Nikolas Evripidou; Tereza Alecou; Marinos Giannakou; Georgios Menikou; Georgios Constantinides; Christakis Damianou
Journal:  J Med Ultrasound       Date:  2021-05-31

3.  MR relaxation times of agar-based tissue-mimicking phantoms.

Authors:  Anastasia Antoniou; Leonidas Georgiou; Theodora Christodoulou; Natalie Panayiotou; Cleanthis Ioannides; Nikolaos Zamboglou; Christakis Damianou
Journal:  J Appl Clin Med Phys       Date:  2022-04-12       Impact factor: 2.243

4.  Comparison of computer simulations and clinical treatment results of magnetic resonance-guided focused ultrasound surgery (MRgFUS) of uterine fibroids.

Authors:  Mikko Hyvärinen; Yuexi Huang; Elizabeth David; Kullervo Hynynen
Journal:  Med Phys       Date:  2022-03-02       Impact factor: 4.506

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.