Literature DB >> 32040916

Infection Screening in Biofluids with Glucose Test Strips.

Michael Bekhit1, Hua-Yu Wang1, Stanton McHardy1, Waldemar Gorski1.   

Abstract

The four glucosyl esters were synthesized and tested for the determination of infection enzyme leukocyte esterase (LE) in human synovial (joint) fluid and urine. The esters acted as LE substrates releasing glucose in a direct proportion to the activity of LE in a sample. The freed glucose was then detected by a coupled-enzyme assay at either a nitrogen-doped carbon nanotube (N-CNT) electrode or a commercial glucose test strip. The assays at the N-CNT electrode detected LE down to 0.81 nM (25 μg L-1) and showed the fastest kinetics (2.1 × 105 M-1 s-1) for esters with the least crowded space around their carbonyl group. When used with glucose strips, the esters discerned clinically relevant levels of LE up to at least 26 nM (800 μg L-1) in the microliter-sized samples of bodily fluids. The reading of glucose strips with a potentiostat, instead of a personal glucose meter (blood glucometer), shortened the time of required sample incubation from 3 h to 5 min. Correcting the signal of incubated sample for that of original sample eliminated matrix effects and accounted for the presence of native glucose. The new esters have a potential to extend the use of glucose strips (already used by millions for diabetes monitoring) to the quantification of the severity of urinary tract and periprosthetic joint infections.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32040916     DOI: 10.1021/acs.analchem.9b05313

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Diagnostic Accuracy for Periprosthetic Joint Infection Does Not Improve by a Combined Use of Glucose and Leukocyte Esterase Strip Reading as Diagnostic Parameters.

Authors:  Marco Haertlé; Louisa Kolbeck; Christian Macke; Tilman Graulich; Ricarda Stauß; Mohamed Omar
Journal:  J Clin Med       Date:  2022-05-25       Impact factor: 4.964

2.  What Is the Optimal Timing for Reading the Leukocyte Esterase Strip for the Diagnosis of Periprosthetic Joint Infection?

Authors:  Qing-Yuan Zheng; Rui Li; Ming Ni; Peng Ren; Quan-Bo Ji; Jing-Yang Sun; Jun-Cheng Li; Ji-Ying Chen; Guo-Qiang Zhang
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

Review 3.  Application of leukocyte esterase strip test in the screening of periprosthetic joint infections and prospects of high-precision strips.

Authors:  Qing-Yuan Zheng; Guo-Qiang Zhang
Journal:  Arthroplasty       Date:  2020-10-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.