Literature DB >> 32040883

Bipolar Directional Deep Brain Stimulation in Essential and Parkinsonian Tremor.

Julia K Steffen1, Paul Reker1, Fiona K Mennicken1, Till A Dembek1, Haidar S Dafsari1, Gereon R Fink1,2, Veerle Visser-Vandewalle3, Michael T Barbe1.   

Abstract

OBJECTIVE: To compare directional monopolar, bipolar, and directional bipolar thalamic deep brain stimulation (DBS) in tremor patients.
METHODS: Fourteen tremor patients (7 Essential Tremor and 7 Parkinson's Disease) implanted with directional DBS electrodes in the ventral intermediate nucleus (VIM) were enrolled. Side-effect thresholds of monopolar directional stimulation (DIRECT) were compared to circular DBS as well as, in a randomized design, to those of two different bipolar stimulation settings (BIPOLAR = circular anode; BI-DIRECT = directional anode). Tremor suppression (Tremor Rating Scale, TRS) right below the side-effect threshold was also assessed.
RESULTS: Directional DBS in the individually best direction showed higher side-effect thresholds than circular DBS (p = 0.0063). The thresholds were raised further using either one of the bipolar stimulation paradigms (BIPOLAR p = 0.0029, BI-DIRECT p = 0.0022). The side-effect thresholds did not differ between both bipolar settings, but side-effects were less frequent with BI-DIRECT. No difference in TRS scores with stimulation just below the side-effect threshold was found between all stimulation conditions.
CONCLUSIONS: Side-effect thresholds of monopolar directional and bipolar stimulation with both circular and directional anodes were higher compared to traditional monopolar circular stimulation in the VIM. Bipolar DBS with directional anodes evoked side-effect less frequently than bipolar and monopolar directional stimulation. All stimulation settings had comparable effects on tremor suppression just below their side-effect thresholds. Thus, directional and different bipolar settings should be explored in patients with bothersome side-effects of thalamic stimulation when monopolar stimulation settings are not satisfying. Further studies are needed to explore the efficiency of the different bipolar stimulation paradigms.
© 2020 The Authors. Neuromodulation: Technology at the Neural Interface published by Wiley Periodicals, Inc. on behalf of International Neuromodulation Society.

Entities:  

Keywords:  Deep brain stimulation; Parkinson's disease; essential tremor

Mesh:

Year:  2020        PMID: 32040883     DOI: 10.1111/ner.13109

Source DB:  PubMed          Journal:  Neuromodulation        ISSN: 1094-7159


  3 in total

1.  Parkinson´s and Alzheimer´s Diseases and Natural Products: Pathologies and Medication of the New Times.

Authors:  Seyed Mohammad Nabavi; Eduardo Sobarzo-Sánchez
Journal:  Curr Neuropharmacol       Date:  2021       Impact factor: 7.363

2.  Surgical Strategy for Directional Deep Brain Stimulation.

Authors:  Hiroshi Masuda; Hiroshi Shirozu; Yosuke Ito; Masafumi Fukuda; Yukihiko Fujii
Journal:  Neurol Med Chir (Tokyo)       Date:  2021-10-29       Impact factor: 1.742

3.  An in-silico assessment of efficacy of two novel intra-cardiac electrode configurations versus traditional anti-tachycardia pacing therapy for terminating sustained ventricular tachycardia.

Authors:  Shuang Qian; Adam Connolly; Caroline Mendonca-Costa; Fernando Campos; Steven E Williams; John Whitaker; Christopher A Rinaldi; Martin J Bishop
Journal:  Comput Biol Med       Date:  2021-10-30       Impact factor: 4.589