Sarah Coggins1, Mary Catherine Harris2, Robert Grundmeier3, Elizabeth Kalb4, Ursula Nawab2, Lakshmi Srinivasan5. 1. Department of Pediatrics, Division of Neonatology, Children's Hospital of Philadelphia, Philadelphia, PA. 2. Department of Pediatrics, Division of Neonatology, Children's Hospital of Philadelphia, Philadelphia, PA; Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA. 3. Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA; Department of Pediatrics, Division of General Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA; Department of Biomedical and Health Informatics, Children's Hospital of Philadelphia, Philadelphia, PA. 4. Department of Pediatrics, Division of General Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA. 5. Department of Pediatrics, Division of Neonatology, Children's Hospital of Philadelphia, Philadelphia, PA; Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA. Electronic address: srinivasanl@email.chop.edu.
Abstract
OBJECTIVES: To evaluate accuracy of systemic inflammatory response syndrome (SIRS) criteria in identifying culture-proven late-onset neonatal sepsis and to assess prevalence of organ dysfunction and its relationship with SIRS criteria. STUDY DESIGN: This was a retrospective case-control study of patients in the Children's Hospital of Philadelphia level IV neonatal intensive care unit undergoing sepsis evaluations (concurrent blood culture and antibiotics). During calendar years 2016-2017, 77 case and 77 control sepsis evaluations were identified. Cases included infants who had sepsis evaluations with positive blood cultures and antibiotic duration ≥7 days. Controls were matched by gestational and postmenstrual age, and had sepsis evaluations with negative blood cultures and antibiotic duration ≤48 hours. SIRS criteria were determined at time of sepsis evaluation, and organ dysfunction evaluated in the 72 hours following sepsis evaluation. Statistical analysis included descriptive statistics, Mann-Whitney tests, and χ2 (Fisher exact) tests. RESULTS: At time of sepsis evaluation, 42% of cases and 26% of controls met SIRS criteria. Among infants of ≤37 weeks postmenstrual age, SIRS criteria were met in only 17% of sepsis evaluations (4 of 23 in both cases and controls). Test characteristics for SIRS at diagnosis of culture-proven sepsis included sensitivity 42% and specificity 74%. Cases had higher rates of new organ dysfunction within 72 hours (40% vs 21%); however, 58% of cases developing organ dysfunction did not meet SIRS criteria at time of sepsis evaluation. Of 6 deaths (all cases with organ dysfunction), 2 did not meet SIRS criteria at sepsis evaluation. CONCLUSIONS: SIRS criteria did not accurately identify culture-proven late-onset sepsis, with poorest accuracy in preterm infants. SIRS criteria did not predict later organ dysfunction or mortality.
OBJECTIVES: To evaluate accuracy of systemic inflammatory response syndrome (SIRS) criteria in identifying culture-proven late-onset neonatal sepsis and to assess prevalence of organ dysfunction and its relationship with SIRS criteria. STUDY DESIGN: This was a retrospective case-control study of patients in the Children's Hospital of Philadelphia level IV neonatal intensive care unit undergoing sepsis evaluations (concurrent blood culture and antibiotics). During calendar years 2016-2017, 77 case and 77 control sepsis evaluations were identified. Cases included infants who had sepsis evaluations with positive blood cultures and antibiotic duration ≥7 days. Controls were matched by gestational and postmenstrual age, and had sepsis evaluations with negative blood cultures and antibiotic duration ≤48 hours. SIRS criteria were determined at time of sepsis evaluation, and organ dysfunction evaluated in the 72 hours following sepsis evaluation. Statistical analysis included descriptive statistics, Mann-Whitney tests, and χ2 (Fisher exact) tests. RESULTS: At time of sepsis evaluation, 42% of cases and 26% of controls met SIRS criteria. Among infants of ≤37 weeks postmenstrual age, SIRS criteria were met in only 17% of sepsis evaluations (4 of 23 in both cases and controls). Test characteristics for SIRS at diagnosis of culture-proven sepsis included sensitivity 42% and specificity 74%. Cases had higher rates of new organ dysfunction within 72 hours (40% vs 21%); however, 58% of cases developing organ dysfunction did not meet SIRS criteria at time of sepsis evaluation. Of 6 deaths (all cases with organ dysfunction), 2 did not meet SIRS criteria at sepsis evaluation. CONCLUSIONS: SIRS criteria did not accurately identify culture-proven late-onset sepsis, with poorest accuracy in preterm infants. SIRS criteria did not predict later organ dysfunction or mortality.