Jonathan R Weir-McCall1, Adrian Attinger-Toller2, Philipp Blanke3, Gidon Y Perlman4, Stephanie L Sellers3, David Wood5, John G Webb5, Jonathon Leipsic3. 1. Department of Radiology, St. Paul's Hospital, Vancouver, British Columbia, Canada; University of Cambridge School of Clinical Medicine, Cambridge, UK. Electronic address: jw2079@cam.ac.uk. 2. Department of Cardiology, St. Paul's Hospital, Vancouver, British Columbia, Canada; Department of Cardiology, Fribourg University and Hospital, Fribourg, Switzerland. 3. Department of Radiology, St. Paul's Hospital, Vancouver, British Columbia, Canada. 4. Department of Cardiology, Hadassah Hebrew University Medical Center, Jerusalem, Israel. 5. Department of Cardiology, St. Paul's Hospital, Vancouver, British Columbia, Canada.
Abstract
BACKGROUND: CT measurement of supra-annular area (SA) has been proposed as an alternative to annular area (AA) for sizing of trancatheter valves in biscuspid aortic valves (BAV). This study examines the reproducibility of SA and AA measurements and their potential impact on downstream transcatheter heart valve sizing and clinical outcomes. METHODS: 44 consecutive patients (mean age: 73 ± 15 years, 57% male) undergoing CTA with subsequent SAPIEN 3 valve insertion for severe bicuspid aortic stenosis (AS) were included. AA was measured at the basal ring. SA was measured by generating a circle defined by the intercommisural distance. AA and SA were measured by 2 independent observers. Baseline characteristics, TAVR procedural data, and discharge echocardiography data were collected. RESULTS: The SA was significantly larger than the AA (562 ± 146mm2 vs. 518 ± 112mm2,p = 0.013). Interobserver agreement was high using both techniques (ICC AA = 0.98,p < 0.001; SA = 0.80,p < 0.001), but with narrower limits of agreement with AA measurements (mean difference (limits of agreement): AA = -3mm2 (22; 19), SA = -16mm2 (-92; 76)). AA-based device sizing demonstrated substantial agreement with final valve inserted (κ = 0.72,p < 0.001), while SA demonstrated fair agreement (κ = 0.40,p < 0.001). There was no difference in post TAVR gradients, paravalvular leakage or valve success between patients with concordant sizing between AA and SA, and those in whom SA would have suggested an alternate valve size. CONCLUSIONS: Supra-annular sizing is less reproducible than annular sizing, with no difference in procedural complication rates in patients in whom supra-annular sizing would have altered the device size used. These results suggest no role for supra-annular sizing in current clinical practice.
BACKGROUND: CT measurement of supra-annular area (SA) has been proposed as an alternative to annular area (AA) for sizing of trancatheter valves in biscuspid aortic valves (BAV). This study examines the reproducibility of SA and AA measurements and their potential impact on downstream transcatheter heart valve sizing and clinical outcomes. METHODS: 44 consecutive patients (mean age: 73 ± 15 years, 57% male) undergoing CTA with subsequent SAPIEN 3 valve insertion for severe bicuspid aortic stenosis (AS) were included. AA was measured at the basal ring. SA was measured by generating a circle defined by the intercommisural distance. AA and SA were measured by 2 independent observers. Baseline characteristics, TAVR procedural data, and discharge echocardiography data were collected. RESULTS: The SA was significantly larger than the AA (562 ± 146mm2 vs. 518 ± 112mm2,p = 0.013). Interobserver agreement was high using both techniques (ICC AA = 0.98,p < 0.001; SA = 0.80,p < 0.001), but with narrower limits of agreement with AA measurements (mean difference (limits of agreement): AA = -3mm2 (22; 19), SA = -16mm2 (-92; 76)). AA-based device sizing demonstrated substantial agreement with final valve inserted (κ = 0.72,p < 0.001), while SA demonstrated fair agreement (κ = 0.40,p < 0.001). There was no difference in post TAVR gradients, paravalvular leakage or valve success between patients with concordant sizing between AA and SA, and those in whom SA would have suggested an alternate valve size. CONCLUSIONS: Supra-annular sizing is less reproducible than annular sizing, with no difference in procedural complication rates in patients in whom supra-annular sizing would have altered the device size used. These results suggest no role for supra-annular sizing in current clinical practice.
Authors: Tian-Yuan Xiong; Walid Ben Ali; Yuan Feng; Kentaro Hayashida; Hasan Jilaihawi; Azeem Latib; Michael Kang-Yin Lee; Martin B Leon; Raj R Makkar; Thomas Modine; Christoph Naber; Yong Peng; Nicolo Piazza; Michael J Reardon; Simon Redwood; Ashok Seth; Lars Sondergaard; Edgar Tay; Didier Tchetche; Wei-Hsian Yin; Mao Chen; Bernard Prendergast; Darren Mylotte Journal: Nat Rev Cardiol Date: 2022-06-20 Impact factor: 32.419
Authors: Aleksandra Gasecka; Michał Walczewski; Adam Witkowski; Maciej Dabrowski; Zenon Huczek; Radosław Wilimski; Andrzej Ochała; Radosław Parma; Piotr Scisło; Bartosz Rymuza; Karol Zbroński; Piotr Szwed; Marek Grygier; Anna Olasińska-Wiśniewska; Dariusz Jagielak; Radosław Targoński; Grzegorz Opolski; Janusz Kochman Journal: Front Cardiovasc Med Date: 2022-06-21
Authors: Todd C Villines; Subhi J Al'Aref; Daniele Andreini; Marcus Y Chen; Andrew D Choi; Carlo N De Cecco; Damini Dey; James P Earls; Maros Ferencik; Heidi Gransar; Harvey Hecht; Jonathon A Leipsic; Michael T Lu; Mohamed Marwan; Pál Maurovich-Horvat; Edward Nicol; Gianluca Pontone; Jonathan Weir-McCall; Seamus P Whelton; Michelle C Williams; Armin Arbab-Zadeh; Gudrun M Feuchtner Journal: J Cardiovasc Comput Tomogr Date: 2021-02-22
Authors: Ahmed Elkoumy; John Jose; Christian J Terkelsen; Henrik Nissen; Sengottuvelu Gunasekaran; Mahmoud Abdelshafy; Ashok Seth; Hesham Elzomor; Sreenivas Kumar; Francesco Bedogni; Alfonso Ielasi; Santosh K Dora; Sharad Chandra; Keyur Parikh; Daniel Unic; William Wijns; Andreas Baumbach; Darren Mylotte; Patrick Serruys; Osama Soliman Journal: J Clin Med Date: 2022-01-15 Impact factor: 4.241