Literature DB >> 32029112

Miniature and fully portable gradient capillary liquid chromatograph.

Shing Chung Lam1, Lewellwyn Joseph Coates2, Mohamed Hemida1, Vipul Gupta3, Paul R Haddad1, Mirek Macka4, Brett Paull5.   

Abstract

A robust, portable and miniature battery powered gradient capillary liquid chromatograph (total weight ∼2.7 kg, without battery ∼2.0 kg), with integrated microfluidic injection, column heating and high sensitivity low-UV absorbance detection is presented. The portable capillary chromatograph, was applied with a packed reversed-phase capillary column (100 mm × 300 μm I.D., 5 μm ODS), housed within an integrated capillary column heater controlled by a proportional-integral-derivative (PID) chip module. The system delivered retention time and peak area relative standard deviation in isocratic mode of <0.7% (n = 10) and <3.3% (n = 10), respectively, and <0.1% (n = 10) and <2.3% (n = 10) respectively, for gradient elution mode. Detection was based upon a 255 nm light-emitting diode (LED) using one of two commercial capillary flow-cell options, namely a high sensitivity 12 nL Agilent capillary z-cell (HSDC) and a 45 nL Thermo Fisher Scientific UZ-View™ flow cell (UZFC). The HSDC, housed within a 3D printed detector arrangement, gave an effective pathlength of 1.01 mm (84% of nominal pathlength) and stray light of only 0.2%. Limits of detection for four test small molecule pharmaceuticals ranged from 65 to 101 μg L-1 based upon a 316 nL injection volume, with separation efficiencies of between 18,000 and 29,700 N m-1, with sub-4 min run times. The portable capillary LC system was successfully coupled to a small footprint portable mass spectrometer (Microsaic 4500 MiD) to demonstrate compatibility and 'point-of-need' miniaturised LC-MS capability.
Copyright © 2019 Elsevier B.V. All rights reserved.

Keywords:  Capillary liquid chromatography; Column heater; Miniaturisation; Portable; Portable mass spectrometer; Ultraviolet light-emitting diode-based detector

Mesh:

Substances:

Year:  2019        PMID: 32029112     DOI: 10.1016/j.aca.2019.12.014

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Peak broadening caused by using different micro-liquid chromatography detectors.

Authors:  Tobias Werres; Torsten C Schmidt; Thorsten Teutenberg
Journal:  Anal Bioanal Chem       Date:  2022-06-15       Impact factor: 4.478

2.  Portable capillary liquid chromatography for pharmaceutical and illicit drug analysis.

Authors:  Samuel W Foster; Xiaofeng Xie; Michelle Pham; Paul A Peaden; Leena M Patil; Luke T Tolley; Paul B Farnsworth; H Dennis Tolley; Milton L Lee; James P Grinias
Journal:  J Sep Sci       Date:  2020-02-05       Impact factor: 3.645

Review 3.  Low-cost and open-source strategies for chemical separations.

Authors:  Joshua J Davis; Samuel W Foster; James P Grinias
Journal:  J Chromatogr A       Date:  2020-12-24       Impact factor: 4.759

Review 4.  Chromatographic-Based Platforms as New Avenues for Scientific Progress and Sustainability.

Authors:  José S Câmara; Cátia Martins; Jorge A M Pereira; Rosa Perestrelo; Sílvia M Rocha
Journal:  Molecules       Date:  2022-08-18       Impact factor: 4.927