Literature DB >> 3202625

Legionella spp. in Puerto Rico cooling towers.

A Negrón-Alvíra1, I Pérez-Suarez, T C Hazen.   

Abstract

Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.

Entities:  

Mesh:

Year:  1988        PMID: 3202625      PMCID: PMC204250          DOI: 10.1128/aem.54.10.2331-2334.1988

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  10 in total

1.  Isolation of Legionella pneumophila from nonepidemic-related aquatic habitats.

Authors:  C B Fliermans; W B Cherry; L H Orrison; L Thacker
Journal:  Appl Environ Microbiol       Date:  1979-06       Impact factor: 4.792

2.  Isolation of the Legionnaires' disease bacterium from environmental samples.

Authors:  G K Morris; C M Patton; J C Feeley; S E Johnson; G Gorman; W T Martin; P Skaliy; G F Mallison; B D Politi; D C Mackel
Journal:  Ann Intern Med       Date:  1979-04       Impact factor: 25.391

3.  Autecology of Legionella pneumophila.

Authors:  C B Fliermans
Journal:  Zentralbl Bakteriol Mikrobiol Hyg A       Date:  1983-07

4.  Ecological distribution of Legionella pneumophila.

Authors:  C B Fliermans; W B Cherry; L H Orrison; S J Smith; D L Tison; D H Pope
Journal:  Appl Environ Microbiol       Date:  1981-01       Impact factor: 4.792

5.  Isolation of Legionella spp. from environmental water samples by low-pH treatment and use of a selective medium.

Authors:  C A Bopp; J W Sumner; G K Morris; J G Wells
Journal:  J Clin Microbiol       Date:  1981-04       Impact factor: 5.948

6.  Abundance and distribution of Legionellaceae in Puerto Rican waters.

Authors:  C M Ortiz-Roque; T C Hazen
Journal:  Appl Environ Microbiol       Date:  1987-09       Impact factor: 4.792

7.  Legionnaires' disease in the Caribbean. An outbreak associated with a resort hotel.

Authors:  W F Schlech; G W Gorman; M C Payne; C V Broome
Journal:  Arch Intern Med       Date:  1985-11

8.  Simultaneous determination of the total number of aquatic bacteria and the number thereof involved in respiration.

Authors:  R Zimmermann; R Iturriaga; J Becker-Birck
Journal:  Appl Environ Microbiol       Date:  1978-12       Impact factor: 4.792

Review 9.  Legionella infections: a review of five years of research.

Authors:  R D Meyer
Journal:  Rev Infect Dis       Date:  1983 Mar-Apr

10.  Influence of salinity and organic nutrient concentration on survival and growth of Vibrio cholerae in aquatic microcosms.

Authors:  F L Singleton; R W Attwell; M S Jangi; R R Colwell
Journal:  Appl Environ Microbiol       Date:  1982-05       Impact factor: 4.792

  10 in total
  5 in total

1.  Factors stimulating propagation of legionellae in cooling tower water.

Authors:  H Yamamoto; M Sugiura; S Kusunoki; T Ezaki; M Ikedo; E Yabuuchi
Journal:  Appl Environ Microbiol       Date:  1992-04       Impact factor: 4.792

Review 2.  Epidemiology, prevention and control of legionellosis: memorandum from a WHO meeting.

Authors: 
Journal:  Bull World Health Organ       Date:  1990       Impact factor: 9.408

3.  Relationship between Legionella spp. and antibody titres at a therapeutic thermal spa in Portugal.

Authors:  G Rocha; A Veríssimo; R Bowker; N Bornstein; M S Da Costa
Journal:  Epidemiol Infect       Date:  1995-08       Impact factor: 2.451

4.  Adaptation of amoebae to cooling tower biocides.

Authors:  S Srikanth; S G Berk
Journal:  Microb Ecol       Date:  1994-05       Impact factor: 4.552

5.  Distribution of Legionella spp. in hydrothermal areas in continental Portugal and the island of São Miguel, Azores.

Authors:  A Veríssimo; G Marrão; F G da Silva; M S da Costa
Journal:  Appl Environ Microbiol       Date:  1991-10       Impact factor: 4.792

  5 in total