| Literature DB >> 32026002 |
Kumi Fukuhara1, Takashi Kondo2, Hirotsugu Miyoshi2, Hiroshi Hamada2, Masashi Kawamoto2.
Abstract
BACKGROUND: Changes in coagulability during the hyperacute phase within 24 h after transcatheter aortic valve implantation (TAVI) for Heyde's syndrome, or aortic stenosis complicated by gastrointestinal angiodysplasia and acquired coagulation dysfunction, have not been clarified. We evaluated perioperative changes in coagulability using rotational thromboelastometry (ROTEM). CASEEntities:
Keywords: Heyde’s syndrome; Rotational thromboelastometry; Transcatheter aortic valve implantation
Year: 2019 PMID: 32026002 PMCID: PMC6966723 DOI: 10.1186/s40981-019-0224-3
Source DB: PubMed Journal: JA Clin Rep ISSN: 2363-9024
Fig. 1a Results of preoperative analysis of vWF multimers. b Results of postoperative analysis of vWF multimers
Blood testing findings
| Before surgery | 6 h after surgery | 24 h after surgery | 3 days after surgery | |
|---|---|---|---|---|
| Plt (× 103/μL) [150–360] | 80 | 63 | 61 | 69 |
| PT-INR [0.85–1.15] | 1.02 | 1.1 | 1.07 | 1.05 |
| APTT (s) [26.9–38.1] | 32.9 | 38.8 | 39.7 | 35 |
| Fib (mg/dL) [200–400] | 225.6 | 189.5 | 239.9 | 319.2 |
Plt platelet count, PT-INR prothrombin time-international normalized ratio, APTT activated partial thromboplastin time, Fib fibrinogen
ROTEM findings
| Before surgery | 6 h after surgery | 12 h after surgery | 24 h after surgery | 3 days after surgery | |
|---|---|---|---|---|---|
| EXTEM | |||||
| CT (s) [38–79] | 59 | 50 | 54 | 57 | 51 |
| CFT (s) [34–159] | 200 | 130 | 123 | 131 | 103 |
| A10 (mm) [43–65] | 35 | 44 | 44 | 44 | 49 |
| MCF (mm) [50–72] | 44 | 52 | 52 | 53 | 56 |
| INTEM | |||||
| CT (s) [100–240] | 308 | 403 | 191 | 240 | 157 |
| CFT (s) [30–110] | 190 | 182 | 123 | 127 | 102 |
| A10 (mm) [44–66] | 38 | 37 | 43 | 44 | 47 |
| MCF (mm) [50–72] | 47 | 46 | 51 | 51 | 52 |
| FIBTEM | |||||
| A10 (mm) [7–23] | 13 | 14 | – | 13 | 16 |
| MCF (mm) [9–25] | 14 | 15 | – | 14 | 19 |
Units are given in parentheses and reference ranges are given in square brackets
ROTEM rotational thromboelastometry, EXTEM tissue factor reagent, INTEM contact coagulation activator reagent, FIBTEM modified EXTEM test with a platelet aggregation inhibitor, CT clotting time, CFT clot formation time, A10 amplitude at 10 min, MCF maximum clot firmness