Literature DB >> 32025968

Anesthetic management of an infant with Pierre Robin sequence undergoing tracheostomy using an i-gel™.

Keisuke Omiya1, Takashi Matsukawa2.   

Abstract

Entities:  

Keywords:  I-gel™; Infant; Pierre Robin sequence; Tracheostomy

Year:  2019        PMID: 32025968      PMCID: PMC6967293          DOI: 10.1186/s40981-019-0231-4

Source DB:  PubMed          Journal:  JA Clin Rep        ISSN: 2363-9024


× No keyword cloud information.
To the Editor: Pierre Robin sequence (PRS) is defined as the clinical triad of micrognathia, glossoptosis, and airway obstruction. Proper airway management is necessary during infancy because children with PRS frequently experience respiratory failure in early life [1]. There are some reports that a laryngeal mask airway (LMA) and the Air-Q® (Mercury Medical, Clearwater, FL, USA) are effective for airway management in patients with PRS [2, 3]. There are also some reports that the i-gel™ (Intersurgical, Wokingham, UK) is more effective than an LMA because inserting an i-gel™ takes less time than inserting an LMA [4, 5]; furthermore, the i-gel™ has greater leak pressure than the LMA [5]. However, there are no case reports regarding tracheostomy of infants with PRS, especially young infants approximately 1 month old, using an i-gel™. Therefore, we evaluated the use of the i-gel™ as a supraglottic airway device (SGA) during this procedure. The patient was a 46-day-old boy with a height of 49 cm and a weight of 2.6 kg. He was born at 37 weeks and weighed 1970 g. He was diagnosed with PRS because he had micrognathia and a cleft palate at birth. The patient’s pharyngeal view was categorized as Mallampati class IV. It was possible to fit a mask to his face. A tracheostomy was scheduled because of worsening airway obstruction. Preanesthetic medication was not administered. An intravenous catheter was placed before the patient entered the operating room. Electrocardiography, percutaneous oxygen saturation, and noninvasive arterial blood pressure were monitored after the patient entered the operating room. We induced general anesthesia after preoxygenating the patient with 5 L/min oxygen for 3 min. First, we administered 0.06 mg intravenous injection (IV) atropine, 6 μg IV fentanyl, and 6 mg IV propofol. We were able to provide ventilation via a mask; subsequently, we administered 3 mg of IV rocuronium. We then attempted to intubate the patient with an uncuffed endotracheal tube (3.0 mm internal diameter) using an AirWay Scope™ (AWS™, Pentax, Humburg, DE). However, we could not visualize the vocal cords (Cormach-Lehane grade 4). We knew that attempts at tracheal intubation frequently lead to laryngeal edema and the inability to provide ventilation. Therefore, we inserted an i-gel™ (size1). We were able to provide ventilation via the i-gel™, and thought that it would be possible to perform a tracheostomy if we could provide ventilation via the i-gel™ using rocuronium to open the glottis. Anesthesia was maintained with a gas mixture of oxygen, air (fraction of inspired oxygen (FIO2), 0.3–0.7) and sevoflurane (1–1.5%), and remifentanil (0.1–0.5 μg/kg/min) and rocuronium (single injection of 1.5 mg) were administered. We were able to perform a tracheostomy and surgery without complications. We successfully used an i-gel™ for anesthetic management of an infant with PRS who was undergoing tracheostomy.
  5 in total

Review 1.  Diagnosis and treatment of the Pierre Robin sequence: results of a retrospective clinical study and review of the literature.

Authors:  A P van den Elzen; B A Semmekrot; E M Bongers; P L Huygen; H A Marres
Journal:  Eur J Pediatr       Date:  2001-01       Impact factor: 3.183

2.  [Successful tracheal intubation using the pediatric Airtraq optical laryngoscope in a pediatric patient with Robin sequence].

Authors:  Hidetaka Iwai; Riichiro Kanai; Yuko Takaku; Yoshihiro Hirabayashi; Norimasa Seo
Journal:  Masui       Date:  2011-02

3.  A randomised trial comparing the i-gel (TM) with the LMA Classic (TM) in children.

Authors:  J-R Lee; M-S Kim; J-T Kim; H-J Byon; Y-H Park; H-S Kim; C-S Kim
Journal:  Anaesthesia       Date:  2012-02-21       Impact factor: 6.955

4.  A two-stage approach to induction and intubation of two infants with Pierre Robin Sequence using a LMA Classic™ and Air-Q®: two cases report.

Authors:  T Wesley Templeton; Yvon F Bryan
Journal:  Korean J Anesthesiol       Date:  2016-07-01

5.  A comparison of i-gel™ and Laryngeal Mask Airway Supreme™ during general anesthesia in infants.

Authors:  Yoon Chan Lee; Kyoung Seop Yoon; Sang Yoong Park; So Ron Choi; Chan Jong Chung
Journal:  Korean J Anesthesiol       Date:  2017-08-14
  5 in total