Literature DB >> 32025529

Thyroid Fine-Needle Aspiration and Smearing Techniques.

Mitsuyoshi Hirokawa1, Ayana Suzuki2, Akira Miyauchi3.   

Abstract

Introduction: Thyroid fine-needle aspiration cytology is the most reliable preoperative diagnostic tool, but cases of failed or unsatisfactory diagnostic can occur. Therefore, we aim to improve aspiration and smearing techniques. We handle approximately 8000 thyroid fine-needle aspiration cytology cases annually. Here, we present the aspiration and smearing techniques resulting from our accumulated experience. Materials and
Methods: Patients undergo aspiration cytology while seated on a barber chair, and are asked to gaze upwards to extend their anterior neck.1 Instead of relying on suction force, the samples are mainly obtained by cutting the tissue with needle movements. A strong negative pressure and a long aspiration time frequently produce bloody samples. Hence, we recommend negative pressure <0.3 mL and aspiration time up to 3 seconds. The obtained samples are placed on a glass slide and smeared using a second slide glass through a press and release method. When the samples are bloody, we tilt the glass slide, remove excess material, and wipe up the bloody components flowing from the slide. Liquid-based cytology is especially recommended for bloody or fluid samples. Biochemical measurement of thyroglobulin and calcitonin using fine-needle washout fluids is useful for diagnosing metastatic differentiated thyroid carcinoma and medullary thyroid carcinoma.2,3 When lymphoma is suspected, flow cytometry using aspirated samples is recommended.4
Results: By applying the mentioned techniques and recommendations, we observed an increased accuracy in diagnosis and improved quality of our examinations. Conclusions: Fine-needle aspiration requires aspirating from the areas suitable for the diagnosis, obtaining adequate materials, and performing optimal smearing and fixation to retrieve highly accurate diagnoses. We hope our methods are helpful in improving your fine-needle aspiration cytology techniques, and result in more accurate cytological diagnoses. Thank you for taking interest in our methods. Acknowledgment: We would like to thank Dr. Louise Davies, Associate Professor of Surgery-Otolaryngology-Head and Neck Surgery, Geisel School of Medicine at Dartmouth, Hanover, NH, for her valuable comments on the creation of this video. We have no connection to any companies or products mentioned in this content. No competing financial interests exist. Runtime of video: 7 mins 15 secs The Japanese version of this video was presented at the 29th Annual Congress of the Japan Association of Endocrine Surgeons, held in May 18, 2017, in Kobe, Japan. © Mitsuyoshi Hirokawa et al. 2018; Published by Mary Ann Liebert, Inc.

Entities:  

Keywords:  fine-needle aspiration; press and release method; smearing technique; thyroid

Year:  2018        PMID: 32025529      PMCID: PMC6961794          DOI: 10.1089/ve.2018.0119

Source DB:  PubMed          Journal:  VideoEndocrinology        ISSN: 2329-9738


  4 in total

1.  Preoperative diagnostic algorithm of primary thyroid lymphoma using ultrasound, aspiration cytology, and flow cytometry.

Authors:  Mitsuyoshi Hirokawa; Takumi Kudo; Hisashi Ota; Ayana Suzuki; Kaoru Kobayashi; Akira Miyauchi
Journal:  Endocr J       Date:  2017-07-08       Impact factor: 2.349

2.  Usefulness of thyroglobulin measurement in fine-needle aspiration biopsy specimens for diagnosing cervical lymph node metastasis in patients with papillary thyroid cancer.

Authors:  Takashi Uruno; Akira Miyauchi; Kazuo Shimizu; Chisato Tomoda; Yuuki Takamura; Yasuhiro Ito; Akihiro Miya; Kaoru Kobayashi; Fumio Matsuzuka; Nobuyuki Amino; Kanji Kuma
Journal:  World J Surg       Date:  2005-04       Impact factor: 3.352

3.  Tumor protrusion with intensive blood signals on ultrasonography is a strongly suggestive finding of follicular thyroid carcinoma.

Authors:  Kaoru Kobayashi; Mitsuyoshi Hirokawa; Tomonori Yabuta; Hiroo Masuoka; Mitsuhiro Fukushima; Minoru Kihara; Takuya Higashiyama; Yasuhiro Ito; Akihiro Miya; Nobuyuki Amino; Akira Miyauchi
Journal:  Med Ultrason       Date:  2016-03       Impact factor: 1.611

4.  Diagnosis of medullary thyroid carcinoma by calcitonin measurement in fine-needle aspiration biopsy specimens.

Authors:  Takumi Kudo; Akira Miyauchi; Yasuhiro Ito; Yuuki Takamura; Nobuyuki Amino; Mitsuhiro Hirokawa
Journal:  Thyroid       Date:  2007-07       Impact factor: 6.568

  4 in total
  2 in total

1.  Histological alterations following fine-needle aspiration for parathyroid adenoma: Incidence and diagnostic problems.

Authors:  Mitsuyoshi Hirokawa; Ayana Suzuki; Miyoko Higuchi; Toshitetsu Hayashi; Seiji Kuma; Akihiro Miya; Akira Miyauchi
Journal:  Pathol Int       Date:  2021-03-19       Impact factor: 2.534

2.  Clinical significance and cytological detection of tracheal puncture following thyroid fine-needle aspiration: A retrospective study.

Authors:  Aki Tanaka; Mitsuyoshi Hirokawa; Ayana Suzuki; Miyoko Higuchi; Risa Kanematsu; Naoki Yamao; Seiji Kuma; Toshitetsu Hayashi; Akira Miyauchi
Journal:  Diagn Cytopathol       Date:  2021-07-21       Impact factor: 1.582

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.