Shabnam Thapa 1 , Ruth Wong 1 , Steve Goodacre 2 . Show Affiliations »
Abstract
OBJECTIVES: Recent guidance recommended use of high-sensitivity troponin for rapid rule out of myocardial infarction (MI) in the English health service. We aimed to determine the extent of implementation of this guidance across English hospitals. METHODS: This study conducted a cross-sectional questionnaire survey of 131 English acute hospitals with over 10 000 admissions per year. RESULTS: We received 125/131 responses (95%), with 110/125 (88%) reporting use of a high-sensitivity troponin assay and responses showing progressive implementation over the last 10 years. High-sensitivity troponin was reported to be used for rapid rule out of MI in 92/110 Trusts (84%). Review of guidelines received from 95/110 Trusts identified that 71/95 (75%) provided guidance for rapid MI rule out with high-sensitivity troponin: 57 recommended testing at 0 and 3 hours, 4 recommended testing at 0 and 2 hours, and 9 recommended testing at 0 and 1 hour, and timing was unclear at one Trust. CONCLUSIONS: English acute hospital Trusts report widespread implementation of high-sensitivity troponin for rapid rule out of MI, with most recommending testing at 0 and 3 hours. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.
OBJECTIVES: Recent guidance recommended use of high-sensitivity troponin for rapid rule out of myocardial infarction (MI) in the English health service. We aimed to determine the extent of implementation of this guidance across English hospitals. METHODS: This study conducted a cross-sectional questionnaire survey of 131 English acute hospitals with over 10 000 admissions per year. RESULTS: We received 125/131 responses (95%), with 110/125 (88%) reporting use of a high-sensitivity troponin assay and responses showing progressive implementation over the last 10 years. High-sensitivity troponin was reported to be used for rapid rule out of MI in 92/110 Trusts (84%). Review of guidelines received from 95/110 Trusts identified that 71/95 (75%) provided guidance for rapid MI rule out with high-sensitivity troponin: 57 recommended testing at 0 and 3 hours, 4 recommended testing at 0 and 2 hours, and 9 recommended testing at 0 and 1 hour, and timing was unclear at one Trust. CONCLUSIONS: English acute hospital Trusts report widespread implementation of high-sensitivity troponin for rapid rule out of MI, with most recommending testing at 0 and 3 hours. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.
Entities: Disease
Keywords:
guidelines; myocardial infarction; troponin
Mesh: See more »
Substances: See more »
Year: 2020
PMID: 32024642 DOI: 10.1136/emermed-2019-209100
Source DB: PubMed Journal: Emerg Med J ISSN: 1472-0205 Impact factor: 2.740