Literature DB >> 32023232

What Is the Reliability of a New Classification for Bone Defects in Revision TKA Based on Preoperative Radiographs?

Maartje Belt1,2, Katrijn Smulders1,2, Albert van Houten1,2, Ate Wymenga1,2, Petra Heesterbeek1,2, Gijs van Hellemondt1,2.   

Abstract

BACKGROUND: Accurate quantification of bone loss facilitates preoperative planning and standardization for research purposes in patients who undergo revision TKA. The most commonly used classification to rate bone defects in this setting, the Anderson Orthopaedic Research Institute classification, does not quantify diaphyseal bone loss and reliability has not been well studied. QUESTIONS/PURPOSES: We developed a new classification scheme to rate bone defects in patients undergoing revision TKA and tested (1) the intraobserver and interobserver reliability of this classification for revision TKA based on preoperative radiographs, and (2) whether additional CT images might improve interobserver reliability.
METHODS: This was a preregistered observational study. Interobserver reliability was analyzed using preoperative radiographs of 61 patients who underwent (repeat) revision TKA, and their bone defects were rated by five experienced orthopaedic surgeons. For intraobserver reliability, ratings were repeated at least 2 weeks after the first rating (Timepoints 1 and 2). Directly after the radiographic assessments of Timepoint 2, the observers were provided with CT images of each patient and asked to rate the bone defects for a third time (Timepoint 3), to assess the additional value of CT. Intraobserver and interobserver reliability were tested using Gwet's agreement coefficient 2, which is a measure of agreement between observers in categorical data. Substantial agreement was defined as coefficients between 0.61 to 0.8 and almost perfect agreement as > 0.8.
RESULTS: The intraobserver reliability varied between 0.55 (95% CI 0.40 to 0.71) and 0.87 (95% CI 0.78 to 0.96) in the epiphysis, between 0.69 (95% CI 0.58 to 0.80) and 0.98 (95% CI 0.95 to 1) in the metaphysis, and between 0.95 (95% CI 0.90 to 0.99) and 0.99 (95% CI 0.98 to 1) in the diaphysis. The interobserver reliability varied between 0.48 (95% CI 0.39 to 0.57) and 0.49 (95% CI 0.42 to 0.56) in the epiphysis and between 0.81 (95% CI 0.75 to 0.87) and 0.88 (95% CI 0.83 to 0.93) in the metaphysis, and was 0.96 (95% CI 0.93 to 0.99) in the diaphysis at Timepoint 1. The interobserver reliability at Timepoint 2 was similar to that of Timepoint 1. The addition of CT images did not improve reliability (Timepoint 3).
CONCLUSIONS: The bone defect classification was less reliable in the epiphyseal area compared with the metaphysis and diaphysis. This finding may be explained by prosthetic components obscuring this region or the more severe bone defects in this region. The addition of CT scans did not improve reliability. Further testing of reliability with observers from other institutions is necessary, as well as validity testing, by testing the classification in relation to intraoperative findings. LEVEL OF EVIDENCE: Level III, diagnostic study.

Entities:  

Mesh:

Year:  2020        PMID: 32023232      PMCID: PMC7431257          DOI: 10.1097/CORR.0000000000001084

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

Review 1.  Bone defect classifications in revision total knee arthroplasty, their reliability and utility: a systematic review.

Authors:  Yasim Khan; Sumit Arora; Abhishek Kashyap; Mohit Kumar Patralekh; Lalit Maini
Journal:  Arch Orthop Trauma Surg       Date:  2022-07-03       Impact factor: 3.067

2.  CORR Insights®: What is the Reliability of a New Classification for Bone Defects in Revision TKA Based on Preoperative Radiographs?

Authors:  Charles N Cornell
Journal:  Clin Orthop Relat Res       Date:  2020-09       Impact factor: 4.755

Review 3.  Management of bone loss in revision total knee arthroplasty: therapeutic options and results.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Carlos A Encinas-Ullán
Journal:  EFORT Open Rev       Date:  2021-11-19

4.  A prospective study on outcome of patient-specific cones in revision knee arthroplasty.

Authors:  Alexander A Cherny; Anton N Kovalenko; Taras A Kulyaba; Nikolai N Kornilov
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-15       Impact factor: 3.067

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.