Literature DB >> 32020456

Selective and simultaneous detection of cadmium, lead and copper by tapioca-derived carbon dot-modified electrode.

Musa Yahaya Pudza1, Zurina Zainal Abidin2, Suraya Abdul-Rashid1, Faizah Md Yasin1, Ahmad Shukri Muhammad Noor3, Jaafar Abdullah4.   

Abstract

The need for the sensing of environmental pollutants cannot be overemphasized in the twenty-first century. Herein, a sensor has been developed for the sensitive and selective detection of copper (Cu2+), lead (Pb2+) and cadmium (Cd2+) as major heavy metals polluting water environment. A screen-printed carbon electrode (SPCE) modified by fluorescent carbon dots (CDs) and gold nanoparticles (AuNPs) was successfully fabricated for sensing Cu2+, Pb2+ and Cd2+. Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were deployed for the analysis of ternary analytes. CV was set at a potential range of - 0.8 to + 0.2 V at a scan rate of 100 mV/s, and DPV at a potential range of - 0.8 to + 0.1 V, scan rate of 50 mV/s, pulse rate of 0.2 V and pulse width of 50 ms. DPV technique was applied through the modified electrode for sensitive and selective determination of Cu2+, Pb2+ and Cd2+ at a concentration range of 0.01 to 0.27 ppm for Cu2+, Pb2+ and Cd2+. Tolerance for the highest possible concentration of foreign substances such as Mg2+, K+, Na+, NO3-, and SO42- was observed with a relative error less than ± 3%. The sensitivity of the modified electrode was at 0.17, 0.42 and 0.18 ppm for Cd2+, Pb2+ and Cu2+, respectively, while the limits of detection (LOD) achieved for cadmium, lead and copper were 0.0028, 0.0042 and 0.014 ppm, respectively. The quality of the modified electrode for sensing Cu2+, Pb2+ and Cd2+ at trace levels is in accordance with the World Health Organization (WHO) and Environmental Protection Agency (EPA) water regulation standard. The modified SPCE provides a cost-effective, dependable and stable means of detecting heavy metal ions (Cu2+, Pb2+ and Cd2+) in an aqueous solution. Graphical abstract .

Entities:  

Keywords:  Detection; Electrochemical; Electrode; Heavy metals; Screen printed

Mesh:

Substances:

Year:  2020        PMID: 32020456     DOI: 10.1007/s11356-020-07695-7

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  1 in total

1.  Studies on a glutathione coated hollow ZnO modified glassy carbon electrode; a novel Pb(ii) selective electrochemical sensor.

Authors:  Lateef Ahmad Malik; Altaf Hussain Pandith; Arshid Bashir; Aaliya Qureashi; Taniya Manzoor
Journal:  RSC Adv       Date:  2021-05-20       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.