Flexural strength, fracture toughness, three-body wear, and Martens parameters of pressable lithium-X-silicate ceramics.

Bogna Stawarczyk1, Lina Dinse2, Marlis Eichberger2, Rebecca Jungbauer2, Anja Liebermann2.   

Abstract

OBJECTIVES: To test and compare five pressable lithium-X-silicate-ceramics on their mechanical and wear properties.
METHODS: Specimens were pressed and prepared from: i. Amber Press (AP), ii. Celtra Press (CP), iii. Initial LiSi Press (IL), iv. Livento Press (LP), and v. IPS e.max Press (IE). Four-point flexural strength (FS), SEVNB fracture toughness (KIC), three-body wear (3BW), Martens hardness (HM) and indentation modulus (EIT) were measured. For CP, FS and HM were measured with and without additional Power Firing. Each subgroup contained 15 specimens. Data were analyzed using Kolmogorov-Smirnov, one-way ANOVA followed by Scheffé test, Kruskal-Wallis-H-, Mann-Whitney-U-, and Spearman-Rho-test (p < 0.05). The Weibull modulus was calculated using the maximum likelihood estimation method.
RESULTS: AP and CP presented higher FS than IL. LP presented the highest Weibull modulus. CP showed lower KIC values than AP, and AP was not significant compared to LP and IE. The most 3BW material loss was observed for CP. CP revealed higher HM values than the remaining ceramics. IL presented lower EIT compared to AP and CP. The following correlations were observed between the test parameters: 3BW with FS (r = 0.279, p = 0.015), with HM (r = -0.378, p = 0.001), and with EIT (r = -0.344, p = 0.004); EIT with FS (r = 0.203, p = 0.028); and HM with FT (r = -0.223, p = 0.027) and EIT (r = 0.884, p < 0.001). No correlations were observed between FS and KIC (r = 0.046; p = 0.346). SIGNIFICANCE: AP followed by LP showed the highest and IL followed by CP the lowest properties tested. Power Firing of CP improved the flexural strength. Ceramics with high flexural strength and Martens parameters showed lower wear. Materials with high Martens hardness presented lower fracture toughness values and ones with high indentation modulus showed high flexural strength.
Copyright © 2020 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Four-point flexural strength; Indentation modulus; Lithium disilicate; Lithium silicate; Martens hardness; Mechanical properties; Pressable ceramic; SEVNB fracture toughness; Three-body wear

Mesh:

Substances:

Year:  2020        PMID: 32007315     DOI: 10.1016/j.dental.2020.01.009

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  1 in total

1.  Comparative analysis of flexural strength of abraded and polished porcelain surfaces - an in vitro study.

Authors:  Prathibha Nandagiri; Mamidi Praveen; Shikha Singh; Monika Singh; Namratha Chandrahari; Fayez Hussain Niazi
Journal:  J Med Life       Date:  2021 Jan-Mar
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.