Ketil Kvam1, Aesha Irkayek2, Eliza Vangaeva2, Fadi El-Homsi2.
Abstract
Objectives: The aim is to compare the adhesion between zirconia and cements attained with melt-etching with potassium hydrogen difluoride, KHF2, with that found when such traditional surface treatments as sandblasting and ceramic stone grinding are employed. Materials and methods: Groups of zirconia crowns where treated by sandblasting (n = 6), grinding with carbide bur (n = 6) or melt-etching with KHF2 (n = 6) of the surface before cementation with a resin cement to an implant substitute made by Selective Laser Melting of a cobalt-chromium alloy. Tensile testing was performed to rupture, while measured increasing load at the zirconia-cement interface. The strength was calculated by dividing the rupture load with the contact area. The three groups were compared using one-way ANOVA.Entities:
Keywords: Zirconia surface treatments; adhesion strength; tensile test
Year: 2019 PMID: 31998867 PMCID: PMC6964774 DOI: 10.1080/23337931.2019.1621179
Source DB: PubMed Journal: Biomater Investig Dent ISSN: 2641-5275
Materials used in the experiments.
| Material | Producer | City, Country | Batch-nr. |
|---|---|---|---|
| Prettau Zirkonia (Y-TZP) | Zirkonzahn | Gais, Italy | ZB7287N |
| remanium® star CL (CoCr-alloy) | Concept Laser GmbH | Lichtenfels, Germany | 460121A |
| Potassium hydrogen difluoride, KHF2, Purum p.a. | Honeywell | Seelze, Germany | H054A |
| Multilink Hybrid Abutment | Ivoclar Vivadent AG | Schaan, Liechtenstein | V17296 |
Figure 1.Dimensions and 3D view of the cobalt-chromium implant substitutes.
Figure 2.Crowns de-bonded from implant substitutes when the insides of the crowns are (a) sandblasted, (b) ground and (c) melt-etched with potassium hydrogen difluoride.
Figure 3.Potassium hydrogen difluoride crushed in a mortar and filled in crowns before melt-etching.
Figure 4.Inner surfaces of crowns, visualized in stereo microscope after (a) sandblasting, (b) grinding and (c) melt etching.
Figure 5.The tensile system schematically drawn with one of the group 3C abutment substitutes.
Results of tensile testing at rupture, mean values and standard deviations.
| Group | Bond strength (MPa) | Standard deviation (MPa) | |
|---|---|---|---|
| Sandblasted | 751 | 5.2 | 0.95 |
| Ground | 1067 | 7.3 | 1.49 |
| Etched | 1426 | 9.8 | 1.37 |