Literature DB >> 31994455

Adaptive Ultrasound Tissue Harmonic Imaging Based on an Improved Ensemble Empirical Mode Decomposition Algorithm.

Suya Han1, Yufeng Zhang1, Keyan Wu1, Bingbing He1, Kexin Zhang2, Hong Liang1.   

Abstract

Complete and accurate separation of harmonic components from the ultrasonic radio frequency (RF) echo signals is essential to improve the quality of harmonic imaging. There are limitations in the existing two commonly used separation methods, that is, the subjectivity for the high-pass filtering (S_HPF) method and motion artifacts for the pulse inversion (S_PI) method. A novel separation method called S_CEEMDAN, based on the complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) algorithm, is proposed to adaptively separate the second harmonic components for ultrasound tissue harmonic imaging. First, the ensemble size of the CEEMDAN algorithm is calculated adaptively according to the standard deviation of the added white noise. A set of intrinsic mode functions (IMFs) is then obtained by the CEEMDAN algorithm from the ultrasonic RF echo signals. According to the IMF spectra, the IMFs that contain both fundamental and harmonic components are further decomposed. The separation process is performed until all the obtained IMFs have been divided into either fundamental or harmonic categories. Finally, the fundamental and harmonic RF echo signals are obtained from the accumulations of signals from these two categories, respectively. In simulation experiments based on CREANUIS, the S_CEEMDAN-based results are similar to the S_HPF-based results, but better than the S_PI-based results. For the dynamic carotid artery measurements, the contrasts, contrast-to-noise ratios (CNRs), and tissue-to-clutter ratios (TCRs) of the harmonic images based on the S_CEEMDAN are averagely increased by 31.43% and 50.82%, 18.96% and 10.83%, as well as 34.23% and 44.18%, respectively, compared with those based on the S_HPF and S_PI methods. In conclusion, the S_CEEMDAN method provides improved harmonic images owing to its good adaptivity and lower motion artifacts, and is thus a potential alternative to the current methods for ultrasonic harmonic imaging.

Keywords:  adaptive signal analysis; complete ensemble empirical mode decomposition; harmonic separation; tissue harmonic imaging; ultrasound

Year:  2020        PMID: 31994455     DOI: 10.1177/0161734619900147

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  1 in total

1.  Comparative analysis of wavelet transform filtering systems for noise reduction in ultrasound images.

Authors:  Dominik Vilimek; Jan Kubicek; Milos Golian; Rene Jaros; Radana Kahankova; Pavla Hanzlikova; Daniel Barvik; Alice Krestanova; Marek Penhaker; Martin Cerny; Ondrej Prokop; Marek Buzga
Journal:  PLoS One       Date:  2022-07-07       Impact factor: 3.752