24-hour blood pressure monitoring: evaluation of Spacelabs 5300 monitor by comparison with intra-arterial blood pressure recording in ambulant subjects.

R Casadei1, G Parati, G Pomidossi, A Groppelli, S Trazzi, M Di Rienzo, G Mancia.   

Abstract

The accuracy of 24-h blood pressure values obtained by ambulatory monitoring via the Spacelabs 5300 device was evaluated by comparison with simultaneous 24-h intra-arterial blood pressure recording from the contralateral arm. The comparison was made in eight essential hypertensive subjects in whom non-invasive blood pressure was measured every 15 (day) or 30 min (night). The measurements were automatically and visually edited to eliminate artefactual readings and hourly and 24-h means were calculated separately for systolic and diastolic blood pressure. The corresponding intra-arterial blood pressure means were also calculated. In the group as a whole, hourly means obtained by the non-invasive device were similar or only slightly different from those recorded intra-arterially. The 24-h systolic blood pressure mean obtained non-invasively was not significantly different from that obtained intra-arterially (138.4 +/- 9.1 and 142.9 +/- 9.2 mmHg, respectively), nor were the corresponding 24-h diastolic blood pressure means significantly different (83.5 +/- 4.5 and 80.6 +/- 3.5 mmHg, respectively). However, in spite of these similarities, there were contrasting and often large discrepancies between non-invasive and intra-arterial values in individual subjects. For the 24-h systolic blood pressure mean the discrepancies ranged from 7.6 +/- 1.1 to 16.1 +/- 2.2 mmHg and for the 24-h diastolic blood pressure mean, from 3.5 to 13.2 mmHg. Thus, the Spacelabs 5300 device has a limited ability to correctly estimate ambulatory blood pressure in individual subjects. It may be better suited for the estimation of group blood pressures, but only because errors are smoothed by the summation of individual errors of opposing signs.

Entities:  

Mesh:

Year:  1988        PMID: 3198917

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  9 in total

1.  Once daily nisoldipine in hypertension: cuff and ambulatory intra-arterial blood pressure.

Authors:  G Brigden; M Heber; M Caruana; A Lahiri; E B Raftery
Journal:  Eur J Clin Pharmacol       Date:  1989       Impact factor: 2.953

2.  Evening vs morning isradipine sustained release in essential hypertension: a double-blind study with 24 h ambulatory monitoring.

Authors:  R Fogari; E Malacco; F Tettamanti; A E Gnemmi; M Milani
Journal:  Br J Clin Pharmacol       Date:  1993-01       Impact factor: 4.335

3.  Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

Authors:  Gianfranco Parati; Stefano Omboni; Paolo Palatini; Damiano Rizzoni; Grzegorz Bilo; Mariaconsuelo Valentini; Enrico Agabiti Rosei; Giuseppe Mancia
Journal:  High Blood Press Cardiovasc Prev       Date:  2013-01-22

4.  Decision to treat mild hypertension after assessment by ambulatory monitoring and World Health Organisation recommendations.

Authors:  G Chatellier; C Battaglia; J Y Pagny; P F Plouin; J Ménard
Journal:  BMJ       Date:  1992-10-31

5.  The 24-hour efficacy of a new once-daily formulation of nifedipine. Italian Nifedipine GITS Study Group.

Authors:  A Zanchetti
Journal:  Drugs       Date:  1994       Impact factor: 9.546

6.  Antihypertensive efficacy of twice daily controlled release diltiazem using 24 hour intra-arterial blood pressure monitoring.

Authors:  B S Sridhara; P Thomas; A Lahiri; E B Raftery
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

7.  Prognostic Significance of Blood Pressure Variability on Beat-to-Beat Monitoring After Transient Ischemic Attack and Stroke.

Authors:  Alastair J S Webb; Sara Mazzucco; Linxin Li; Peter M Rothwell
Journal:  Stroke       Date:  2017-12-11       Impact factor: 7.914

8.  The treatment of mild OSA with CPAP or mandibular advancement device and the effect on blood pressure and endothelial function after one year of treatment.

Authors:  Thais Moura Guimarães; Dalva Poyares; Luciana Oliveira E Silva; Gabriela Luz; Glaury Coelho; Cibele Dal Fabbro; Sergio Tufik; Lia Bittencourt
Journal:  J Clin Sleep Med       Date:  2021-02-01       Impact factor: 4.062

9.  Validation of the Montreal cognitive assessment versus mini-mental state examination against hypertension and hypertensive arteriopathy after transient ischemic attack or minor stroke.

Authors:  Alastair J S Webb; Sarah T Pendlebury; Linxin Li; Michela Simoni; Nicola Lovett; Ziyah Mehta; Peter M Rothwell
Journal:  Stroke       Date:  2014-09-23       Impact factor: 7.914

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.