| Literature DB >> 31988664 |
Sean Michael Lanting1, Martin Jeremy Spink1, Peta Ellen Tehan1,2, Stephanie Vickers1, Sarah Louise Casey1, Vivienne Helaine Chuter1,3.
Abstract
BACKGROUND: Testing of protective sensation and vibration perception are two of the most commonly used non-invasive methods of screening for diabetes-related peripheral neuropathy (DPN). However, there is limited research investigating the reliability of these tests in people with diabetes. The aim of this study was to determine the inter- and intra-rater reliability of methods used to test vibration perception and protective sensation in a community-based population of adults with type 2 diabetes.Entities:
Keywords: Diabetes; Monofilament; Neuropathy; Neurothesiometer; Reliability; Tuning fork; Vibration
Mesh:
Year: 2020 PMID: 31988664 PMCID: PMC6966840 DOI: 10.1186/s13047-020-0371-9
Source DB: PubMed Journal: J Foot Ankle Res ISSN: 1757-1146 Impact factor: 2.303
Participant characteristics
| Monofilament and VPT ( | ||||
|---|---|---|---|---|
| N | Mean Age (SD) | T2-DM | Existing DPN diagnosis | |
| Males | 33 | 72 (11) | 33 | 16 |
| Females | 17 | 73 (7) | 17 | 0 |
| Tuning fork ( | ||||
| N | Mean Age (SD) | T2-DM | Existing DPN diagnosis | |
| Males | 15 | 74 (7) | 15 | 1 |
| Females | 9 | 70 (9) | 9 | 0 |
SD standard deviation, T2 DM type two diabetes, DPN diabetic peripheral neuropathy
Intra-rater reliability reported as Cohen’s К and SE with 95%CI and p-values
| Monofilament and VPT ( | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rater 1 | Rater 2 | Rater 3 | ||||||||||
| Test | K | SE | 95% CI | P | K | SE | 95% CI | P | K | SE | 95% CI | P |
| VPT | 0.52 | 0.15 | 0.21 to 0.82 | 0.01 | 0.78 | 0.10 | 0.58 to 0.98 | 0.02 | 0.72 | 0.13 | 0.46 to 0.98 | < 0.01 |
| Monofilament [ | 0.44 | 0.14 | 0.16 to 0.73 | 0.02 | 0.67 | 0.11 | 0.45 to 0.89 | < 0.01 | 0.34 | 0.15 | 0.06 to 0.63 | 0.02 |
| Monofilament [ | 0.49 | 0.18 | 0.14 to 0.83 | < 0.01 | 0.77 | 0.11 | 0.55 to 0.99 | < 0.01 | 0.44 | 0.18 | 0.09 to 0.79 | < 0.01 |
| Tuning fork ( | ||||||||||||
| Rater 4 | Rater 5 | |||||||||||
| Test | K | SE | 95% CI | P | K | SE | 95% CI | P | ||||
| Graduated | 0.57 | 0.17 | 0.24 to 0.9 | < 0.01 | 0.50 | 0.17 | 0.17 to 0.83 | < 0.02 | ||||
| Conventional (on/off) | 0.57 | 0.16 | 0.26 to 0.88 | < 0.01 | 0.52 | 0.19 | 0.15 to 0.89 | < 0.02 | ||||
| Conventional (dampened) | 0.41 | 0.19 | 0.04 to 0.78 | < 0.05 | 0.49 | 0.18 | 0.14 to 0.84 | < 0.02 | ||||
VPT vibration perception threshold
Inter-rater reliabilty of neurological tests reported as Cohen’s or Fleiss’ K and SE with 95%CI and p-values
| Inter-rater reliability between pairs of raters (n = 50) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rater 1 & 2 | Rater 1 & 3 | Rater 2 & 3 | ||||||||||
| Test | K | SE | 95% CI | P | K | SE | 95% CI | P | K | SE | 95% CI | P |
| VPT | 0.78 | 0.9 | 0.59 to 0.96 | < 0.01 | 0.59 | 0.13 | 0.33 to 0.84 | < 0.01 | 0.48 | 0.14 | 0.21 to 0.75 | < 0.01 |
| Monofilament [ | 0.55 | 0.12 | 0.31 to 0.78 | < 0.01 | 0.57 | 0.12 | 0.33 to 0.80 | < 0.01 | 0.72 | 0.10 | 0.53 to 0.91 | < 0.01 |
| Monofilament [ | 0.57 | 0.14 | 0.30 to0.84 | < 0.01 | 0.50 | 0.14 | 0.18 to 0.82 | < 0.01 | 0.57 | 0.16 | 0.17 to 0.83 | < 0.01 |
| Inter-rater reliability between 3 raters (n = 50) | ||||||||||||
| Test | К | SE | 95% CI | P | ||||||||
| VPT | 0.61 | 0.08 | 0.45 to 0.77 | < 0.01 | ||||||||
| Monofilament [ | 0.61 | 0.08 | 0.45 to 0.77 | 0.01 | ||||||||
| Monofilament [ | 0.54 | 0.08 | 0.38 to 0.70 | 0.02 | ||||||||
| Inter-rater reliability for tuning fork between 2 raters (n = 24) | ||||||||||||
| T1 & T2 ( | SE | 95% CI | P | |||||||||
| Conventional (on/off) | 0.63 | 0.17 | 0.30 to 0.96 | < 0.01 | ||||||||
| Conventional (dampened) | 0.66 | 0.15 | 0.37 to 0.95 | < 0.01 | ||||||||
| Graduated | 0.68 | 0.14 | 0.41 to 0.95 | < 0.01 | ||||||||
VPT vibration perception threshold