Literature DB >> 31987511

Inter- and intra-rater reliability of the OCRA checklist method in video-recorded manual work tasks.

Ida-Märta Rhén1, Mikael Forsman2.   

Abstract

Observation-based risk assessments are often used for evaluation of biomechanical workload and the condition of the workplace ergonomics. However, the inter- and intra-rater reliability of the methods used for the assessments are insufficiently studied. The OCRA checklist method, included as a reference method in the ISO and CEN standards regarding upper limb repetitive risk assessment, was in this study investigated regarding its reliability. Eleven ergonomists were educated within the method. Each ergonomist risk-assessed ten video-recorded manual work tasks, on two occasions. The average inter-rater agreement of the five overall risk levels was 39% and the linearly weighted kappa was 0.43, the intra-rater dittos were 45% and 0.52. Both indicating a moderate reliability, but lower than what could be expected. The levels might be sufficient for coarse surveys. However, for risk assessments before and after an intervention, complementing technical methods should be considered.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Inter-rater reliability; Intra-rater reliability; Observational methods; Risk assessment

Year:  2020        PMID: 31987511     DOI: 10.1016/j.apergo.2019.103025

Source DB:  PubMed          Journal:  Appl Ergon        ISSN: 0003-6870            Impact factor:   3.661


  4 in total

1.  An Analysis of Biomechanical Parameters in OTP Police Physical Intervention Techniques for Occupational Risk Prevention.

Authors:  José C Vera-Jiménez; Felipe L Meléndez-Sánchez; José A Álvarez; Jesús Ayuso
Journal:  Int J Environ Res Public Health       Date:  2022-05-28       Impact factor: 4.614

2.  Evaluation of a New Simplified Inertial Sensor Method against Electrogoniometer for Measuring Wrist Motion in Occupational Studies.

Authors:  Karnica Manivasagam; Liyun Yang
Journal:  Sensors (Basel)       Date:  2022-02-21       Impact factor: 3.576

Review 3.  Reliability Analysis of Observation-Based Exposure Assessment Tools for the Upper Extremities: A Systematic Review.

Authors:  Preston Riley Graben; Mark C Schall; Sean Gallagher; Richard Sesek; Yadrianna Acosta-Sojo
Journal:  Int J Environ Res Public Health       Date:  2022-08-25       Impact factor: 4.614

4.  A Wearable Sensor System for Physical Ergonomics Interventions Using Haptic Feedback.

Authors:  Carl Mikael Lind; Jose Antonio Diaz-Olivares; Kaj Lindecrantz; Jörgen Eklund
Journal:  Sensors (Basel)       Date:  2020-10-23       Impact factor: 3.576

  4 in total