Literature DB >> 31985715

Using an Inertial Device (WIMU PRO) to Quantify Neuromuscular Load in Running: Reliability, Convergent Validity, and Influence of Type of Surface and Device Location.

Carlos D Gómez-Carmona1,2, Alejandro Bastida-Castillo1, Adrián González-Custodio3, Guillermo Olcina3, José Pino-Ortega1.   

Abstract

Gómez-Carmona, CD, Bastida-Castillo, A, González-Custodio, A, Olcina, G, and Pino-Ortega, J. Using an inertial device (WIMU PRO) to quantify neuromuscular load in running: reliability, convergent validity, and influence of type of surface and device location. J Strength Cond Res 34(2): 365-373, 2020-Currently, the use of accelerometers in sport is increasing, and thus, the devices are required to be valid and reliable. This study tested (a) the reliability and validity of WIMU PRO accelerometers to measure PlayerLoad (PL) and (b) the influence of speed, inertial device location, and type of surface where the incremental test is performed. Twenty resistance-trained men (age: 27.32 ± 6.65 years; height: 1.74 ± 0.03 m; body mass: 68.96 ± 4.37 kg; and body mass index: 22.76 ± 1.11 kg·m) volunteered to participate in the study that lasted 5 weeks. Four progressive incremental tests were performed in treadmill and athletic track conditions. External load variable (PL) and physiological variables (heart rate [HR] and SmO2) were recorded by 4 WIMU PRO inertial devices (scapulae, center of mass, knee, and ankle), a GARMIN HR band, and a MOXY near-infrared spectroscopy device, respectively. High reliability was found on both types of surface, showing the best values at the ankle (treadmill: intraclass correlation coefficient [ICC] = 0.99, coefficient of variation [CV] = 4.65%; track: ICC = 0.96, CV = 6.54%). A nearly perfect convergent validity was shown with HRAVG (r = 0.99) and a moderate one with SmO2 (r = -0.69). Significant differences in the PL variable between surfaces were reported in all locations except the scapulae (p = 0.173), and the higher values were found on the track. In the analysis per location, the ankle location reported the highest values at all speeds and on the 2 surfaces analyzed. Assessment needs to be individualized, due to the great variability of gait biomechanics among subjects. The accelerometer location should be chosen according to the purpose of the measurement, with the ankle location being recommended for neuromuscular load analysis in running.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31985715     DOI: 10.1519/JSC.0000000000003106

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  2 in total

1.  Multi-Location External Workload Profile in Women's Basketball Players. A Case Study at the Semiprofessional-Level.

Authors:  Carlos D Gómez-Carmona; David Mancha-Triguero; José Pino-Ortega; Sergio J Ibáñez
Journal:  Sensors (Basel)       Date:  2021-06-22       Impact factor: 3.576

Review 2.  Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis.

Authors:  Lauren C Benson; Anu M Räisänen; Christian A Clermont; Reed Ferber
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  2 in total