Literature DB >> 31985061

Using Meglumine Diatrizoate to improve the accuracy of diagnosis of cracked teeth on Cone-beam CT images.

M Yuan1, A T Gao1, T M Wang1, J H Liang1, G B Aihemati1, Y Cao1, X Xie2, L Y Miao3, Z T Lin1.   

Abstract

AIM: To explore in a laboratory setting the feasibility of using Meglumine Diatrizoate (MD) to improve the accuracy of diagnosis of cracked teeth on cone-beam CT (CBCT) images.
METHODOLOGY: Twenty-four teeth were cracked artificially by soaking them cyclically in liquid nitrogen and hot water. The number and position of crack lines were evaluated with a dental operating microscope and used as the gold standard. The artificially cracked teeth were then examined using routine scanning (RS) and enhanced scanning (ES) modes, respectively. For the ES mode, MD was painted on the surface of the crack lines, and then, CBCT scanning with the same parameters was performed after 10 min. A radiological graduate student and an experienced radiologist evaluated the presence or absence of crack lines, respectively. The differences between the RS and ES modes were determined and assessed using McNemar's test. Inter-examiner agreement and intra-examiner agreement were assessed using kappa analysis.
RESULTS: Fifty-seven crack lines were found in the 24 cracked teeth. In the RS mode, the accuracy of detection of crack lines was 23% (radiological graduate student) and 32% (experienced radiologist), whereas in the ES mode, the accuracy was 61% (radiological graduate student) and 65% (experienced radiologist). The inter-examiner agreement was 0.693 in RS mode and 0.849 in ES mode. The intra-examiner agreement was 0.872 and 0.949 for the radiological graduate student in RS and ES mode respectively; and one for the experienced radiologist both in RS and ES mode.
CONCLUSIONS: Compared with routine scanning mode, more crack lines could be detected in enhanced scanning mode using Meglumine Diatrizoate as a contrast medium. MD could be a potential contrast medium to improve the accuracy of detection of crack lines on CBCT images.
© 2020 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  cone-beam CT; cracked tooth; diagnosis; meglumine diatrizoate

Year:  2020        PMID: 31985061     DOI: 10.1111/iej.13270

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  6 in total

1.  Comparison of diagnosis of cracked tooth using contrast-enhanced CBCT and micro-CT.

Authors:  ZiYang Hu; TieMei Wang; Xiao Pan; DanTong Cao; JiaHao Liang; AnTian Gao; Xin Xie; Shi Xu; LeiYing Miao; ZiTong Lin
Journal:  Dentomaxillofac Radiol       Date:  2021-04-20       Impact factor: 3.525

2.  Laboratory simulation of longitudinally cracked teeth using the step-stress cyclic loading method.

Authors:  F Lin; R Ordinola-Zapata; H Xu; Y C Heo; A Fok
Journal:  Int Endod J       Date:  2021-05-05       Impact factor: 5.165

Review 3.  Diagnosis of cracked teeth using cone-beam computed tomography: literature review and clinical experience.

Authors:  Antian Gao; Dantong Cao; Zitong Lin
Journal:  Dentomaxillofac Radiol       Date:  2021-04-29       Impact factor: 3.525

4.  New technique for detecting cracked teeth and evaluating the crack depth by contrast-enhanced cone beam computed tomography: an in vitro study.

Authors:  Jie Zhou; Jieni Fu; Mo Xiao; Feng Qiao; Tiantian Fu; Yangyang Lv; Fei Wu; Cuicui Sun; Peng Li; Ligeng Wu
Journal:  BMC Oral Health       Date:  2022-03-02       Impact factor: 2.757

Review 5.  Recent Advances in the Diagnosis of Enamel Cracks: A Narrative Review.

Authors:  Bassam Zidane
Journal:  Diagnostics (Basel)       Date:  2022-08-22

Review 6.  Review of Cracked Tooth Syndrome: Etiology, Diagnosis, Management, and Prevention.

Authors:  Fei Li; Yaoyao Diao; Jiayin Wang; Xingyu Hou; Shuzhan Qiao; Jiawen Kong; Yunhan Sun; Eui-Seok Lee; Heng Bo Jiang
Journal:  Pain Res Manag       Date:  2021-12-15       Impact factor: 3.037

  6 in total