An anti-factor IXa/factor X bispecific antibody, emicizumab, improves ex vivo coagulant potentials in plasma from patients with acquired hemophilia A.

Masahiro Takeyama1, Keiji Nogami1, Tomoko Matsumoto1,2, Mariko Noguchi-Sasaki3, Takehisa Kitazawa3, Midori Shima1.   

Abstract

INTRODUCTION: Acquired hemophilia A (AHA) is caused by autoantibodies against factor (F)VIII, and is characterized by severe, spontaneous bleeding, which can be life-threatening. Emicizumab, an anti-FIXa/FX bispecific antibody, significantly reduces bleeding events in congenital hemophilia A (HA) with and without inhibitors. The known pathophysiological mechanisms and current preclinical data in HA suggest that emicizumab could provide effective treatment for AHA, but the coagulation activities of emicizumab in these patients remain unknown. AIM: To evaluate the coagulant effects of emicizumab in plasma from AHA patients. METHODS AND
RESULTS: Tissue factor-triggered thrombin generation assays using normal plasma preincubated with anti-FVIII monoclonal antibodies recognizing different epitopes demonstrated that 20 µg/mL emicizumab recovered the depressed peak levels of thrombin generation to 46% to 72%. Further studies were devised, therefore, to simulate the clinical course in AHA patients, including during the acute phase for severe bleeding requiring FVIII-bypassing therapy, and during the subacute/chronic phase with less bleeding. Various concentrations of emicizumab were used to represent the potential changes in plasma levels based on the half-life of the antibody (~30 days). The ex vivo addition of emicizumab to plasma samples from AHA patients (n = 16) increased peak thrombin in all cases, irrespective of the inhibitor epitope specificity. Thrombin generation at 20 and 100 µg/mL emicizumab was restored to (median) 43.9% and 92.2%, respectively. Differences were evident in some cases, however, and recovery rates appeared likely to be greater in patients with type 2 inhibitor than those with type 1.
CONCLUSION: Emicizumab improved ex vivo coagulation potential in plasma from AHA patients.
© 2020 International Society on Thrombosis and Haemostasis.

Entities:  

Keywords:  autoantibodies; bispecific antibodies; blood coagulation; hemophilia A; pharmacokinetics

Mesh:

Substances:

Year:  2020        PMID: 31984625     DOI: 10.1111/jth.14746

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  1 in total

1.  Reduced-intensity, risk factor-stratified immunosuppression for acquired hemophilia A: single-center observational study.

Authors:  Christiane Dobbelstein; Georgios Leandros Moschovakis; Andreas Tiede
Journal:  Ann Hematol       Date:  2020-07-03       Impact factor: 3.673

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.