Intermachine Variation of Ultrasound Strain Elastographic Measures of the Quadriceps and Patellar Tendons in Healthy Participants: Implications for Clinical Practice.

Diane M Dickson1, Henrietta O Fawole1,2, Gordon J Hendry1, Stephanie L Smith1.   

Abstract

OBJECTIVES: To evaluate intermachine variation and compare intraoperator and interoperator agreement and repeatability characteristics of 2 ultrasound (US) systems for measurements of quadriceps and patellar tendons by strain elastography (SE).
METHODS: Forty tendons from 20 healthy participants were investigated by operators with different experience (operator 1, 12 years of US experience and >50 SE examinations; operator 2, no US experience and 1 day of SE training). Repeated measures were performed on GE Healthcare (Waukesha, WI) and Esaote (Genoa, Italy) US systems. The percentage of agreement, Cohen κ, intraclass correlation coefficient, and correlation tests assessed agreement, repeatability, and associations of SE measures. A paired t test and Wilcoxon signed rank test assessed differences in SE measures.
RESULTS: The study participants included 5 male and 15 female volunteers (mean [range] age, 29.3 [21-39] years). Better agreement and repeatability characteristics were observed for the patellar compared to the quadriceps tendon and the color score (CS) method over the elasticity ratio (ER). Intraoperator agreement was better for the experienced operator. Intraoperator repeatability was achieved in 55% of ER (intraclass correlation coefficient, 0.40-0.91; P < .05) and 77% to 85% (κ = -0.25-1) of CS measures. Interoperator repeatability was achieved in 35% (t/z, -2.93-7.94; P < .001-.048) of all ER measures. No significant differences in proximal (z, -0.13- -0.78) and distal patellar (z, -1.52-2.26; P > .5) patellar ER measures were observed. Seventy-four percent to 75% mean agreement (κ = 0-0.5) for CS measures comparable across both US systems was observed. Intermachine ER associations were poor (r = -0.39-0.13; P > .05), whereas greater than 70% agreement (κ = -0.87-0.53) for the CS was achieved.
CONCLUSIONS: The reproducibility of knee tendon SE measurements is influenced by the operator experience, US system, and tendon site.
© 2020 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  comparison; elastography; healthy participants; knee tendon; ultrasound

Mesh:

Year:  2020        PMID: 31981428     DOI: 10.1002/jum.15228

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Concurrent validity and intrarater reliability of two ultrasound-based methods for assessing patellar tendon stiffness.

Authors:  P Henriksen; K Brage; T Junge; B Juul-Kristensen; J Bojsen-Møller; J B Thorlund
Journal:  Ultrasound       Date:  2021-02-21

2.  Changes in stiffness of the specific regions of knee extensor mechanism after static stretching.

Authors:  Yuanchun Zhu; Yanan Feng; Fangchao Huang; Yapeng Li; Wenjing Wang; Xueqiang Wang; Xiangyang Cao; Zhijie Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-08-15

3.  Strain sonoelastography in asymptomatic individuals and individuals with knee osteoarthritis: an evaluation of quadriceps and patellar tendon.

Authors:  Diane M Dickson; Stephanie L Smith; Gordon J Hendry
Journal:  Rheumatol Int       Date:  2022-08-17       Impact factor: 3.580

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.