Smartphone Data Capture Efficiently Augments Dictation for Knee Arthroscopic Surgery.

Joseph Featherall1, Sameer R Oak, Gregory J Strnad, Lutul D Farrow, Morgan H Jones, Anthony A Miniaci, Richard D Parker, James T Rosneck, Paul M Saluan, Kurt P Spindler.   

Abstract

INTRODUCTION: The objectives of this study are (1) to develop a provider-friendly, evidence-based data capture system for lower-limb orthopaedic surgeries and (2) to assess the performance of the data capture system on the dimensions of agreement with operative note and implant log, consistency of data, and speed of provider input.
METHODS: A multidisciplinary team developed a database and user interfaces for Android and iOS operating systems. Branching logic and discrete fields were created to streamline provider data input. One hundred patients were randomly selected from the first four months of data collection (February to June 2015). Patients were limited to those undergoing anterior cruciate ligament reconstruction, meniscal repair, partial meniscectomy, or a combination of these procedures. Duplicate data on these 100 patients were collected through chart review. These two data sets were compared. Cohen's kappa statistic was used to assess agreement.
RESULTS: The database and smartphone data capture tool show almost perfect agreement (kappa > 0.81) for all data tested. In addition, data are more comprehensive with near-perfect provider completion (100% for all data tested). Furthermore, provider data entry is extremely efficient (median 151-second completion time).
CONCLUSION: A well-designed database and user-friendly interface have greater potential for research utility, clinical efficiency, and, thus, cost-effectiveness when compared with standard voice-dictated operative notes. Widespread utilization of such tools can accelerate the pace and improve the quality of orthopaedic clinical research. LEVEL OF EVIDENCE: Level IV.

Entities:  

Year:  2020        PMID: 31977610      PMCID: PMC6964865          DOI: 10.5435/JAAOS-D-19-00074

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


As health care becomes increasingly value driven, the ability to justify treatment is enhanced by prospective, high-quality, standardized databases.[1] Examples of large anterior cruciate ligament reconstruction (ACLR) databases include the Swedish National Anterior Cruciate Ligament (ACL) Register (SNKRL), Danish Cruciate Ligament Registry (DKKR), Kaiser Permanente Anterior Cruciate Ligament Reconstruction Registry (KPACLRR), and the Multicenter Orthopaedic Outcomes Network and Multicenter ACL Revision Study cohort.[23456] The uses of high-quality surgical data include, but are not limited to, internal quality improvement initiatives, large-scale comparative effectiveness research, outcomes research, cost-effectiveness research, and clinical trials.[7-9] Such data have greatly contributed to our understanding of surgical practice.[10] The availability of prospective, standardized, high-quality data is a foundational component for the advancement of the field of orthopaedic surgery. Several practical challenges exist in constructing large high-quality data sets. Much of the important data that are captured in the electronic medical record (EMR) cannot be accessed easily for statistical analysis.[11] Error rates in the manual extraction of data from EMRs have been reported from 8% to 23%, with data varying by site, clinical area, and surgical specialty.[12] Increasing the accuracy of such data through quality assurance and data review increases cost.[12] Operative reports, a key data source for surgical research, tend to infrequently report quantitative data, markedly limiting the precision of research and quality measurement.[13] Even best-in-class registry data are collected through a secured web-based or paper form, which have obvious limitations in workflow (both), data accessibility (paper), and an exhaustivity of 85% to 90% for surgeon-reported data.[10] To further advance orthopaedic outcomes measurement nationally, investigators developed the OrthoMiDaS (Orthopaedic Minimal Data Set) Episode of Care (OME) database and data collection methodology. OME's goal is to accurately and consistently collect patient-reported outcome measures (PROMs) immediately before and at the time of peak function after high-volume elective orthopaedic surgeries, as well as to accurately and consistently collect information about the actual surgical intervention in a manner that is both faster and more detailed than previously designed outcomes database systems. This study describes the development of the OME database and provider-friendly, evidence-based smartphone data collection methodology and assesses the performance of the OME data capture system on the dimensions of agreement with operative note and implant log, consistency of data, and speed of provider input. We hypothesized that the use of the unique, provider-friendly, smartphone-based OME data capture system would increase the quality of orthopaedic procedure data in the context of ACLR and meniscal repair arthroscopic procedures.

Methods

OrthoMiDaS Episode of Care Database Design

A multidisciplinary team including administrators, orthopaedic surgeons, and software developers was assembled for design purposes. The OME database collects the following two distinct classes of data: PROMs and procedural data about the orthopaedic surgery itself. PROMs collected for arthroscopic knee surgeries include the Knee injury and Osteoarthritis Score, The Hospital for Special Surgery Pediatric Functional Activity Brief Scale, and the Veterans Rand 12-Item Health Survey.[14151617] Upon check-in at the surgery center, patients receive an iPad with their PROM form and complete it before going back into the preoperative holding area. This process is designed to be built into the standard clinical workflow so as not to slow down the operating rooms or require any additional staffing to execute. The second class of data, the procedural details about surgery, are entered into OME by the surgeons themselves immediately after surgery using their hospital-issued smartphones or desktop/laptop computers (Figure 1). Demographics such as height, weight examination under anesthesia findings, commonly cited operative report parameters, and key predictors of surgical outcomes for ACLR, meniscal repair, and cartilage repair as identified in the literature are collected in the form of discrete data entry fields.[6,18-20] In total, OME currently provides 449 fields in the knee arthroscopy surgery data set. Branching logic is used to streamline provider data input. For primary meniscal repair and ACLR procedures, the branching logic system will require the surgeon to input approximately 13 fields for each meniscal repair and approximately 16 fields for the ACLR. However, the number of fields will expand as complexity increases. The basic set of meniscal pathology and repair data are shown in Appendix 1. Within the user interface, the branching logic displays fields only relevant to the individual procedure and pathology, greatly expediting the data collection process and decreasing the cognitive load on the surgeon. For example, selecting meniscal repair presents the surgeon with repair types, followed by manufacturers of implants/devices, and then specific device/implant offerings by that company, guiding the surgeon to procedure-specific details rather than requiring unnecessary data input as is often the case in EMR template usage. On the morning of surgery, surgeons receive reminder e-mails for each surgery they are about to perform that day with links to the surgeries' corresponding OME surgeon forms; like the PROMs-collection workflow, surgical data collection is built into surgeons' workflows to minimize delays in the daily routine.
Figure 1

OrthoMiDaS Episode of Care iPhone interface demonstrating detailed data capture and speed dial provider–specific templates. ACL = anterior cruciate ligament, ACLR = anterior cruciate ligament reconstruction

OrthoMiDaS Episode of Care iPhone interface demonstrating detailed data capture and speed dial provider–specific templates. ACL = anterior cruciate ligament, ACLR = anterior cruciate ligament reconstruction Architecturally, OME exists as a collection of research electronic data capture (REDCap) databases managed by the custom-built software that manages the multiplatform data entry and distribution.[21,22] All software is hosted locally and was approved by the local institutional review board (IRB) and information security. This study was also approved by the local IRB (IRB# 06-196).

Patient Selection

The OME database was launched on February 18, 2015. One hundred patients undergoing ACLR, meniscal repair, partial meniscectomy, or a combination of these procedures were included in the data set from the first four months of data collection (February through June 2015). All 12 surgeons at the sports health center who performed these procedures were included in the data set.

Data Collection and Validation

OME data used in this study were prospectively captured by the surgeons directly following their surgical procedures and were exported into a study database in an automated fashion. To evaluate the agreement with surgeons' operative dictation and/or implant logs, an independent REDCap database was established. Independent chart review data for comparison were collected from the operative report and the implant log in the Epic EMR system (Epic Systems). Reviewers of the operative report and the implant log were blinded to the OME REDCap results. Before analysis, the two data sets were reviewed for discrepancies, and all unmatching data were rechecked.

Assumptions in Chart Review Data Collection

The following assumptions were made in obtaining chart-reviewed operative dictation data: (1) If only one tunnel or reamer size was specified, both tibial and femoral tunnels were assumed to be the same size. (2) The operative report was used to determine the implant number and type; when a discrepancy or lack of clarity arose, the reviewer deferred to the implant log. (3) If the bone reamer or tunnel sizes were not specified, the graft size was used to approximate the tunnel size. (4) Regarding ACL status, normal status and no status were considered equivalent.

Statistical Analyses

All analyses were performed using R software (R version 3.2.3 [2015-12-10]). Agreement on nominal variables was measured by Cohen's (unweighted) kappa. 0.81 to 1.00 was considered almost perfect agreement; 0.61 to 0.80 was considered substantial agreement; and 0.41 to 0.60 was considered moderate agreement.[23,24] Agreement on numeric variables was measured by the concordance correlation coefficient (CCC). 0.99 to 1.00 was considered almost perfect agreement; 0.95 to 0.99 was considered substantial agreement; 0.90 to 0.95 was considered moderate agreement; and <0.90 was considered poor agreement.[25] Operative report and OME completion rates are presented as percent completion and are compared using the McNemar test (with continuity correction).

Results

Basic Demographics

The sample included 100 patients undergoing arthroscopic ACLR, arthroscopic meniscal repair, or both. The median age of the patients was 23 years (95% confidence interval [CI] [24.2, 28.7]), and 48% (n = 48) were women. This sample included 94 ACLRs, 58 partial meniscectomies, and 26 meniscal repairs as described in Table 1.
Table 1

Knee Arthroscopy Patient Characteristics

FactorN (%)N
Characteristic
 N100
 Female48 (48.0%)
 Median age (95% CI)23 (24.2, 28.7)
 Operative limb100
  Both1 (1.00%)
  Left45 (45.0%)
  Right54 (54.0%)
Medial meniscus
 Meniscus status100
  Complete tear28 (28.0%)
  Normal55 (55.0%)
  Partial tear17 (17.0%)
 Main tear type45
  Bucket-handle9 (20.0%)
  Complex7 (15.6%)
  Horizontal2 (4.44%)
  Longitudinal27 (60.0%)
 Location to horns45
  Both8 (17.8%)
  Posterior only37 (82.2%)
 Location to blood supply36
  Red-red14 (38.9%)
  Red-white16 (44.4%)
  White-white6 (16.7%)
 Main tear length45
  <6 mm5 (11.1%)
  6–10 mm4 (8.89%)
  11–15 mm11 (24.4%)
  16–20 mm18 (40.0%)
  >20 mm7 (15.6%)
 Treatment45
  Abrade + trephine1 (2.22%)
  No treatment for tear9 (20.0%)
  Partial excision15 (33.3%)
  Repair20 (44.4%)
 Repair technique20
  All inside19 (95.0%)
  Both inside-out and all-in1 (5.00%)
 Implant manufacturer20
  Arthrex3 (15.0%)
  Smith & Nephew17 (85.0%)
 Implant system20
  DartStick3 (15.0%)
  FAST-FIX 36017 (85.0%)
 Number of implants Med [Q1, Q3]2.00 [2.00; 3.00]20
Lateral meniscus
 Meniscus status100
  Complete tear48 (48.0%)
  Normal43 (43.0%)
  Partial tear9 (9.00%)
 Main tear type57
  Bucket-handle5 (8.77%)
  Complex12 (21.1%)
  Horizontal3 (5.26%)
  Longitudinal12 (21.1%)
  Oblique/flap9 (15.8%)
  Radial14 (24.6%)
  Root2 (3.51%)
 Location to horns57
  Anterior only4 (7.02%)
  Both13 (22.8%)
  Posterior only40 (70.2%)
 Location to blood supply17
  Red-red3 (17.6%)
  Red-white7 (41.2%)
  White-white7 (41.2%)
 Main tear extent16
  Complete to periphery4 (25.0%)
  Partial, periphery intact12 (75.0%)
 Main tear length57
  <6 mm10 (17.5%)
  6–10 mm14 (24.6%)
  >20 mm11 (19.3%)
  11–15 mm19 (33.3%)
  16–20 mm3 (5.26%)
  >20 mm11 (19.3%)
 Treatment57
  No treatment for tear8 (14.0%)
  Partial excision43 (75.4%)
  Repair6 (10.5%)
 Repair technique6
  All inside5 (83.3%)
  Inside-out1 (16.7%)
 Implant system5
  DartStick1 (20.0%)
  FAST-FIX 3604 (80.0%)
 Number of implants, Med [Q1, Q3]3.00 [2.00; 4.00]5
Anterior cruciate ligament
 ACL status100
  Complete tear91 (91.0%)
  Normal6 (6.00%)
  Partial tear3 (3.00%)
 ACLR performed94
  Primary93 (98.9%)
  Revision1 (1.06%)
 Graft94
  ALLO Achilles5 (5.32%)
  ALLO other (HG, TA, PT, and ITB)1 (1.06%)
  Auto BTB32 (34.0%)
  Auto HG56 (59.6%)
 Number of strands, Med [Q1, Q3]4.00 [1.00; 5.00]94
 Femur tunnel (mm), Med [Q1, Q3]9.00 [8.50; 10.0]94
 Tibia tunnel (mm), Med [Q1, Q3]9.00 [8.62; 10.0]94
 Primary femoral fixation94
  Cross-pin8 (8.51%)
  Interference screw32 (34.0%)
  Suspensory54 (57.4%)
 Primary femoral screw type32
  Bioabsorbable14 (43.8%)
  Metal18 (56.2%)
 Primary tibial fixation94
  Interference screw77 (81.9%)
  Suspensory17 (18.1%)
 Primary tibial screw type77
  Bioabsorbable41 (53.2%)
  Metal26 (33.8%)
  PEEK10 (13.0%)

ACL = anterior cruciate ligament, ACLR = anterior cruciate ligament reconstruction, ALLO = allograft, BTB = bone-patellar tendon-bone, CI 2= confidence interval, HG = hamstring graft, ITB = iliotibial band, PEEK = polyetheretherketone, PT = patellar tendon, TA = tibialis anterior

Knee Arthroscopy Patient Characteristics ACL = anterior cruciate ligament, ACLR = anterior cruciate ligament reconstruction, ALLO = allograft, BTB = bone-patellar tendon-bone, CI 2= confidence interval, HG = hamstring graft, ITB = iliotibial band, PEEK = polyetheretherketone, PT = patellar tendon, TA = tibialis anterior

Agreement

OME and chart-reviewed data comparison showed “near perfect” (kappa ≥ 0.81) or “substantial” to “almost perfect” agreement (CCC > 0.95) for all data tested (Table 2). The highest agreement level among nominal variables occurred in the reporting of graft type (kappa = 1.000, 95% CI [1.000, 1.000]), medial meniscus implant system (kappa = 1.000, 95% CI [1.000, 1.000]), lateral meniscus implant system (kappa = 1.000, 95% CI [1.000, 1.000]), and lateral meniscus treatment (kappa = 1.000, 95% CI [1.000, 1.000]). The lowest degree of agreement occurred in reporting of lateral meniscus status (kappa = 0.859, 95% CI [0.759, 0.960]). For the three numeric variables, the CCC was lowest for femur tunnel size (CCC = 0.977, 95% CI [0.964, 0.985]) and highest for graft strand number (CCC = 0.998, 95% CI [0.997, 0.999]).
Table 2

Agreement Between Chart-Reviewed and OrthoMiDaS Episode of Care Data

MeasurenAgreement Statistic95% Confidence Interval
Operative limb1000.9400.873, 1.000
ACL
 Status1000.9040.716, 1.000
 Graft type931.0001.000, 1.000
 Graft strand number750.998[a]0.997, 0.999
 Femur tunnel size790.977[a]0.964, 0.985
 Primary femoral fixation type940.9610.908, 1.000
 Femoral screw type310.8710.699, 1.000
 Tibial tunnel size790.990[a]0.984, 0.993
 Primary tibial fixation type930.9250.821, 1.000
 Tibial screw type760.9340.860, 1.000
Medial meniscus
 Status1000.8980.812, 0.985
 Treatment370.9520.860, 1.000
 Implant system181.0001.000, 1.000
Lateral meniscus
 Status1000.8590.759, 0.960
 Treatment461.0001.000, 1.000
 Implant system51.0001.000, 1.000

ACL = anterior cruciate ligament

Agreement between numeric variables is measured through the concordance correlation coefficient.

Agreement Between Chart-Reviewed and OrthoMiDaS Episode of Care Data ACL = anterior cruciate ligament Agreement between numeric variables is measured through the concordance correlation coefficient.

Provider Completion Rate

Graft strand number was reported in OME in 100% of the ACLR patients, but only in 80% of the ACLR patients in the operative reports. Femur tunnel size was reported in OME in 100% of the ACLR patients, but only in 85% of the ACLR patients in the operative reports. Tibial tunnel size was reported in OME in 100% of the ACLR patients, but only in 85% of the ACLR patients in the operative reports (Table 3).
Table 3

Provider Data Completion Rates

MeasureOperative ReportOrthoMiDaS Episode of Care DatabaseP Value
n% Completionn% Completion
ACL
 Graft strand number758094100P < 0.001
 Femur tunnel size808594100P < 0.001
 Tibial tunnel size808594100P < 0.001

ACL = anterior cruciate ligament

Provider Data Completion Rates ACL = anterior cruciate ligament

Time

The median provider time to complete the data entry for a single patient was approximately 2 minutes.

Discussion

Although all data tested showed near-perfect agreement, ACL status (kappa = 0.904), lateral meniscus status (kappa = 0.898), femoral screw type (kappa = 0.871), and medial meniscus status (kappa = 0.859) displayed the least agreement of all data tested. Despite the obvious need for accuracy in determining these parameters, a high degree of variability exists in surgeons' operative dictation description of these lesions and implants. Some surgeons provided detailed, quantitative descriptions (eg, 5-mm, full-thickness, radial tear in the posterior horn), whereas other surgeons gave very brief descriptions (eg, small tear in the lateral meniscus), leading to the inability to extract accurate data from the operative report.

Improved Completion Rate

Historically, the operative report is used as a key data source for most orthopaedic retrospective research. Despite widespread use, the quality of these data is limited.[26] Operative reports tend to infrequently report quantitative data, markedly limiting the precision of research and quality measurement.[13] Moreover, late dictation of reports, or dictation by residents, may also increase error rates.[27,28] This error is compounded by errors in data extraction from the medical record itself. This limited quality of data contributes to the large gap, both in validity and reliability, between prospective and retrospective research.[29] Together, these limitations of operative report data delay the progress of the field and cause increased cost burden. Some improvements in the quality of capturing surgical data have been previously made. Customized, computerized, templated operative reporting systems are available and can improve the consistency of reporting of key operative parameters.[30] The branching logic of OME not only improves the completeness of reporting operative parameter details but also maximizes efficiency in data input. Such systems can dramatically decrease completion delays and reduce the cost of surgical documentation.[31] Before this study, templates and computer assistance are effective in increasing the completeness of operative report data.[30] This finding was consistent with our findings that graft strand number, femur tunnel size, and tibial tunnel size were all more frequently collected in the OME data capture system. The OME user interface incorporates dropdown menus that likely function as memory aids for key surgical parameters.[30] The OME computer defaults and branching logic will not accept missing key risk factors identified in the most recent ACLR and meniscal outcomes research.[6,18-20] Branching logic and the smartphone interface speed the data entry process. Finally, an automated e-mail reminder system is used to ensure the high data capture rate.

Limitations

Currently, although the operative report is widely used, no true benchmark exists for operative reporting. Thus, the absolute accuracy of the OME database (ie, OME data compared directly with true occurrences in the operating room) is difficult to assess. However, the present study indicates OME data are consistent with the current most pervasive methodology and demonstrate less information loss.

Conclusion

The OME data capture system demonstrated “almost perfect” agreement (kappa ≥ 0.81) on all 13 nominal variables and “substantial” agreement (CCC > 0.95) to “almost perfect” agreement (CCC > 0.099) on all three numeric variables tested. In addition, the OME data capture system improved the reporting of key operative parameters necessary for outcomes research and internal quality improvement (100% for all data tested). Furthermore, the developers of this system continue to develop branching logic and data capture tools for additional high-volume orthopaedic surgical procedures. Moreover, widespread use of this system can bring the highest level of prospective quality data to everyday surgical practice. Finally, this technology could potentially replace standard narrative/dictation-based operative reporting, and transform observational and retrospective orthopaedic clinical research, to a prospective cohort model.
Data FieldDropdown Selections
Meniscus statusNormal
Complete tear
Partial tear
Previous partial excision
Previous repair
New tearNone
Partial
Complete
Main tear typeOblique/flap
Longitudinal
Bucket-handle
Radial
Root
Horizontal
Complex
Location to hornsAnterior only
Posterior only
Both
Location to blood supplyRed-red
Red-white
White-white
Main tear extentPartial, periphery intact
Complete to periphery
Main tear length (mm)<6 mm
6–10 mm
11–15 mm
16–20 mm
>20 mm
TreatmentNo treatment for tear
Partial excision
Repair
Abrade + trephine
Meniscal transplant
Repair techniqueAll inside
Inside-out
Both inside-out and all in
Outside-in
Number of inside-out and/or outside-in suturesArthrex
Biomet
Covidien
CONMED
Cayenne
DePuy Mitek
Smith & Nephew
Others
Implant systemSelect from preprogrammed implant system library specific to manufacturer selection
Number of implantsSelect integer value between 0 and 10
Discoid meniscusNo
Yes, partial
Yes, complete
  30 in total

1.  Standardizing Patient Outcomes Measurement.

Authors:  Michael E Porter; Stefan Larsson; Thomas H Lee
Journal:  N Engl J Med       Date:  2016-02-11       Impact factor: 91.245

2.  Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support.

Authors:  Paul A Harris; Robert Taylor; Robert Thielke; Jonathon Payne; Nathaniel Gonzalez; Jose G Conde
Journal:  J Biomed Inform       Date:  2008-09-30       Impact factor: 6.317

3.  Current state of anterior cruciate ligament registers.

Authors:  P Boyer; B Villain; A Pelissier; P Loriaut; B Dallaudière; B Dalaudière; P Massin; P Ravaud
Journal:  Orthop Traumatol Surg Res       Date:  2014-10-13       Impact factor: 2.256

4.  Cost-Effectiveness Analysis of Early Reconstruction Versus Rehabilitation and Delayed Reconstruction for Anterior Cruciate Ligament Tears.

Authors:  Richard C Mather; Carolyn M Hettrich; Warren R Dunn; Brian J Cole; Bernard R Bach; Laura J Huston; Emily K Reinke; Kurt P Spindler
Journal:  Am J Sports Med       Date:  2014-05-06       Impact factor: 6.202

5.  The Swedish National Anterior Cruciate Ligament Register: a report on baseline variables and outcomes of surgery for almost 18,000 patients.

Authors:  Mattias Ahldén; Kristian Samuelsson; Ninni Sernert; Magnus Forssblad; Jón Karlsson; Jüri Kartus
Journal:  Am J Sports Med       Date:  2012-09-07       Impact factor: 6.202

6.  Development and validation of a pediatric sports activity rating scale: the Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS).

Authors:  Peter D Fabricant; Alex Robles; Timothy Downey-Zayas; Huong T Do; Robert G Marx; Roger F Widmann; Daniel W Green
Journal:  Am J Sports Med       Date:  2013-07-26       Impact factor: 6.202

7.  Surgery versus physical therapy for a meniscal tear and osteoarthritis.

Authors:  Jeffrey N Katz; Robert H Brophy; Christine E Chaisson; Leigh de Chaves; Brian J Cole; Diane L Dahm; Laurel A Donnell-Fink; Ali Guermazi; Amanda K Haas; Morgan H Jones; Bruce A Levy; Lisa A Mandl; Scott D Martin; Robert G Marx; Anthony Miniaci; Matthew J Matava; Joseph Palmisano; Emily K Reinke; Brian E Richardson; Benjamin N Rome; Clare E Safran-Norton; Debra J Skoniecki; Daniel H Solomon; Matthew V Smith; Kurt P Spindler; Michael J Stuart; John Wright; Rick W Wright; Elena Losina
Journal:  N Engl J Med       Date:  2013-03-18       Impact factor: 91.245

Review 8.  Database and Registry Research in Orthopaedic Surgery: Part 2: Clinical Registry Data.

Authors:  Andrew J Pugely; Christopher T Martin; Jared Harwood; Kevin L Ong; Kevin J Bozic; John J Callaghan
Journal:  J Bone Joint Surg Am       Date:  2015-11-04       Impact factor: 5.284

9.  Assessing the quality of operation notes: a review of 1092 operation notes in 9 UK hospitals.

Authors:  Julia Blackburn
Journal:  Patient Saf Surg       Date:  2016-02-06

Review 10.  The Knee injury and Osteoarthritis Outcome Score (KOOS): from joint injury to osteoarthritis.

Authors:  Ewa M Roos; L Stefan Lohmander
Journal:  Health Qual Life Outcomes       Date:  2003-11-03       Impact factor: 3.186

View more
  1 in total

1.  Associations of preoperative patient mental health status and sociodemographic and clinical characteristics with baseline pain, function, and satisfaction in patients undergoing primary shoulder arthroplasty.

Authors:  Sambit Sahoo; Kathleen A Derwin; Alexander Zajichek; Vahid Entezari; Peter B Imrey; Joseph P Iannotti; Eric T Ricchetti
Journal:  J Shoulder Elbow Surg       Date:  2020-08-26       Impact factor: 3.019

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.