Literature DB >> 31977519

Ultrasound to Detect Central Venous Catheter Placement Associated Complications: A Multicenter Diagnostic Accuracy Study.

Jasper M Smit1, Mark E Haaksma, Endry H T Lim, Thei S Steenvoorden, Michiel J Blans, Frank H Bosch, Manfred Petjak, Ben Vermin, Hugo R W Touw, Armand R J Girbes, Leo M A Heunks, Pieter R Tuinman.   

Abstract

BACKGROUND: Mechanical complications arising after central venous catheter placement are mostly malposition or pneumothorax. To date, to confirm correct position and detect pneumothorax, chest x-ray film has been the reference standard, while ultrasound might be an accurate alternative. The aim of this study was to evaluate diagnostic accuracy of ultrasound to detect central venous catheter malposition and pneumothorax.
METHODS: This was a prospective, multicenter, diagnostic accuracy study conducted at the intensive care unit and postanesthesia care unit. Adult patients who underwent central venous catheterization of the internal jugular vein or subclavian vein were included. Index test consisted of venous, cardiac, and lung ultrasound. Standard reference test was chest x-ray film. Primary outcome was diagnostic accuracy of ultrasound to detect malposition and pneumothorax; for malposition, sensitivity, specificity, and other accuracy parameters were estimated. For pneumothorax, because chest x-ray film is an inaccurate reference standard to diagnose it, agreement and Cohen's κ-coefficient were determined. Secondary outcomes were accuracy of ultrasound to detect clinically relevant complications and feasibility of ultrasound.
RESULTS: In total, 758 central venous catheterizations were included. Malposition occurred in 23 (3.3%) out of 688 cases included in the analysis. Ultrasound sensitivity was 0.70 (95% CI, 0.49 to 0.86) and specificity 0.99 (95% CI, 0.98 to 1.00). Pneumothorax occurred in 5 (0.7%) to 11 (1.5%) out of 756 cases according to chest x-ray film and ultrasound, respectively. In 748 out of 756 cases (98.9%), there was agreement between ultrasound and chest x-ray film with a Cohen's κ-coefficient of 0.50 (95% CI, 0.19 to 0.80).
CONCLUSIONS: This multicenter study shows that the complication rate of central venous catheterization is low and that ultrasound produces a moderate sensitivity and high specificity to detect malposition. There is moderate agreement with chest x-ray film for pneumothorax. In conclusion, ultrasound is an accurate diagnostic modality to detect malposition and pneumothorax.

Entities:  

Year:  2020        PMID: 31977519     DOI: 10.1097/ALN.0000000000003126

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Lung ultrasound and computed tomography to monitor COVID-19 pneumonia in critically ill patients: a two-center prospective cohort study.

Authors:  Micah L A Heldeweg; Jorge E Lopez Matta; Mark E Haaksma; Jasper M Smit; Carlos V Elzo Kraemer; Harm-Jan de Grooth; Evert de Jonge; Lilian J Meijboom; Leo M A Heunks; David J van Westerloo; Pieter R Tuinman
Journal:  Intensive Care Med Exp       Date:  2021-01-25

2.  An interesting case of central venous catheter misplacement.

Authors:  Priyanka Pavithran; Biju Sekhar; Moidu Shameer; Namitha Manchakkal
Journal:  Saudi J Anaesth       Date:  2022-01-04

3.  Inadvertent Vertebral Vein Cannulation: Anatomical Considerations and Practical Aspects.

Authors:  Sonali Vadi
Journal:  Indian J Crit Care Med       Date:  2022-08

4.  Economic Evaluation of Ultrasound-guided Central Venous Catheter Confirmation vs Chest Radiography in Critically Ill Patients: A Labor Cost Model.

Authors:  Enyo A Ablordeppey; Adam M Koenig; Abigail R Barker; Emily E Hernandez; Suzanne M Simkovich; James G Krings; Derek S Brown; Richard T Griffey
Journal:  West J Emerg Med       Date:  2022-09-15

5.  Point-of-care Ultrasound-guided Central Venous Catheter Confirmation in Ultrasound Nonexperts.

Authors:  Enyo A Ablordeppey; Anne M Drewry; Adam L Anderson; Diego Casali; Laura A Wallace; Deborah S Kane; LinLin Tian; Stacey L House; Brian M Fuller; Richard T Griffey; Daniel L Theodoro
Journal:  AEM Educ Train       Date:  2020-10-13

Review 6.  Our Italian experience using lung ultrasound for identification, grading and serial follow-up of severity of lung involvement for management of patients with COVID-19.

Authors:  Luigi Vetrugno; Tiziana Bove; Daniele Orso; Federico Barbariol; Flavio Bassi; Enrico Boero; Giovanni Ferrari; Robert Kong
Journal:  Echocardiography       Date:  2020-04-15       Impact factor: 1.724

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.