Literature DB >> 31977153

Filling the Gap: A Correlation between Objective and Subjective Measures of Injectability.

Thomas E Robinson1, Erik A B Hughes1, Aniruddha Bose1, Elizabeth A Cornish1, Jun Y Teo1, Neil M Eisenstein1, Liam M Grover1, Sophie C Cox1.   

Abstract

Various injectable biomaterials are developed for the minimally invasive delivery of therapeutics. Typically, a mechanical tester is used to ascertain the force required to inject these biomaterials through a given syringe-needle system. However, currently there is no method to correlate the force measured in the laboratory to the perceived effort required to perform that injection by the end user. In this article, the injection force (F) for a variety of biomaterials, displaying a range of rheological properties, is compared with the effort scores from a 50 person panel study. The maximum injection force measured at crosshead speed 1 mm s-1 is a good proxy for injection effort, with an R2 of 0.89. This correlation leads to the following conclusions: participants can easily inject 5 mL of substance for F < 12 N; considerable effort is required to inject 5 mL for 12 N < F < 38 N; great effort is required and <5 mL can be injected for 38 N < F < 64 N; and materials are entirely non-injectable for F > 64 N. These values may be used by developers of injectable biomaterials to make decisions about formulations and needle sizes early in the translational process.
© 2020 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  alginate; biomaterials; cement; injectability; testing methods

Mesh:

Year:  2020        PMID: 31977153     DOI: 10.1002/adhm.201901521

Source DB:  PubMed          Journal:  Adv Healthc Mater        ISSN: 2192-2640            Impact factor:   9.933


  4 in total

1.  Treatment of Ruptured and Nonruptured Aneurysms Using a Semisolid Iodinated Embolic Agent.

Authors:  Zefu Zhang; Hassan Albadawi; Richard J Fowl; Izzet Altun; Marcela A Salomao; Jama Jahanyar; Brian W Chong; Joseph L Mayer; Rahmi Oklu
Journal:  Adv Mater       Date:  2022-01-21       Impact factor: 30.849

Review 2.  Translational Applications of Hydrogels.

Authors:  Santiago Correa; Abigail K Grosskopf; Hector Lopez Hernandez; Doreen Chan; Anthony C Yu; Lyndsay M Stapleton; Eric A Appel
Journal:  Chem Rev       Date:  2021-05-03       Impact factor: 60.622

3.  Local injection of a hexametaphosphate formulation reduces heterotopic ossification in vivo.

Authors:  T E Robinson; N M Eisenstein; S C Cox; R J A Moakes; A M Thompson; Z Ahmed; E A B Hughes; L J Hill; S A Stapley; L M Grover
Journal:  Mater Today Bio       Date:  2020-06-02

4.  Low Acyl Gellan as an Excipient to Improve the Sprayability and Mucoadhesion of Iota Carrageenan in a Nasal Spray to Prevent Infection With SARS-CoV-2.

Authors:  Thomas E Robinson; Richard J A Moakes; Liam M Grover
Journal:  Front Med Technol       Date:  2021-06-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.