Literature DB >> 31973991

Biomechanical Evaluation of Humerus Fracture After Subpectoral Biceps Tenodesis With Interference Screw Versus Unicortical Button.

Mohammed A Khalid1, Randal P Morris1, Natalie Black1, Nicholas H Maassen2.   

Abstract

PURPOSE: To compare the torsional failure strength of the humerus after subpectoral biceps tenodesis with an interference screw versus a unicortical button in a human cadaveric model.
METHODS: Thirteen matched pairs of fresh-frozen human cadaveric upper extremities were randomized to receive either 2.6 × 12 mm unicortical button or 6.25-mm interference screw subpectoral biceps tenodesis. After the procedure, the humeri were loaded into a materials testing machine. The humeri were loaded in external rotation with respect to the elbow at 1.0°/s until failure. Rotation angle to failure, failure torque, energy absorbed, and stiffness were compared by paired t-tests with alpha set at 0.05.
RESULTS: Humeri that were fixed with unicortical buttons showed statistically significant higher rotation to failure (26.87 ± 5.83 vs 19.04 ± 3.86°, P < .001), failure torque (54.11 ± 22.01 vs 44.95 ± 17.47 Nm, P < .001), and energy absorbed (883.93 ± 582.28 vs 451.40 ± 216.19 Nm-Deg, P = .002) than humeri fixed with interference screws.
CONCLUSIONS: In a cadaveric biomechanical model, at time 0, the use of a 2.7 × 12-mm unicortical button fixation in biceps tenodesis resulted in higher loads required to fracture the humerus when compared with a 6.25-mm interference screw fixation in a torsion model. CLINICAL RELEVANCE: This study demonstrates a significant biomechanical difference with regards to fracture of the humerus, between 2 commonly used fixations methods and implant sizes, interference screw, and unicortical button. The results of this study can aid surgeons in implant selection as well as help to improve patient education prior to surgery.
Copyright © 2019 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 31973991     DOI: 10.1016/j.arthro.2019.10.034

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  3 in total

Review 1.  The rate and reporting of fracture after biceps tenodesis: A systematic review.

Authors:  Hailey P Huddleston; Joey S Kurtzman; Samuel Gedailovich; Steven M Koehler; William R Aibinder
Journal:  J Orthop       Date:  2021-11-24

Review 2.  Management of proximal biceps tendon pathology.

Authors:  Simon P Lalehzarian; Avinesh Agarwalla; Joseph N Liu
Journal:  World J Orthop       Date:  2022-01-18

3.  All-Arthroscopic Anatomic Length-Tension Biceps Tenodesis With Unicortical Button.

Authors:  Justin Kyhos; William Haselman; Michael B Banffy
Journal:  Arthrosc Tech       Date:  2021-05-15
  3 in total