Literature DB >> 31972301

Minimally Invasive Endoscopic Aortic Valve Replacement: Operative Results.

Giovanni Domenico Cresce1, Massimo Sella2, Tommaso Hinna Danesi2, Alessandro Favaro2, Loris Salvador2.   

Abstract

To describe our endoscopic aortic valve replacement (E-AVR) technique and to evaluate its early results regardless of the type of prosthetic valve implanted and the patients' characteristics. From July 2013 to September 2018, 125 patients (76 males, mean age 68.8 ± 10.9 years, mean EuroScore II 1.51 ± 1.39) underwent isolated E-AVR due to a severe stenosis in 99 cases and insufficiency in 26 cases. The surgical access was a 3-4 cm working port in the second right intercostal space with no rib-spreading and 3 additional 5 mm miniports for the introduction of a 30-degree thoracoscope, the Chitwood clamp, and the vent line. Cardiopulmonary bypass (CPB) was achieved through a femoro-femoral cannulation. All patients successfully underwent E-AVR. Stended bioprostheses were implanted in 56 cases, Rapid Deployment and Sutureless valves in 23 and 46 cases, respectively. Mean cross-clamping and CPB times were 87.5 ± 22.1 and 126.1 ± 28.4 minutes, respectively, and a significant difference between the types of prostheses was observed: 69.1 ± 15.1 and 106.2 ± 21.8 minutes (Sutureless) vs 93.2 ± 15.1 and 135.5 ± 21.8 minutes (Rapid Deployment) vs 100.6 ± 17.2 and 138.9 ± 21.9 minutes (Stented). Mean ventilation and ICU times and hospital stay were 10.9 ± 39.3 hours, 45.9 ± 58.4 hours, and 8.3 ± 9.3 days, respectively. Thirty-day mortality was 0.8%. One patient (0.8%) needed a re-exploration for bleeding and 3 patients (2.4%) required a new permanent pacemaker implantation. No major neurologic events were observed. No paravalvular leakage was detected at discharge. E-AVR is associated with low mortality and few complications. Sutureless bioprostheses significantly reduce cross-clamping and CPB times. In dedicated centers, this approach may become a valid alternative to other minimally invasive techniques.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bioprostheses; Endoscopic aortic valve replacement; Minimally invasive

Year:  2020        PMID: 31972301     DOI: 10.1053/j.semtcvs.2020.01.002

Source DB:  PubMed          Journal:  Semin Thorac Cardiovasc Surg        ISSN: 1043-0679


  2 in total

Review 1.  Minimally invasive aortic valve surgery.

Authors:  Lorenzo Di Bacco; Antonio Miceli; Mattia Glauber
Journal:  J Thorac Dis       Date:  2021-03       Impact factor: 2.895

2.  The risk factors for delayed recovery in patients with cardiopulmonary bypass: Why should we care?

Authors:  Baozeng Chen; Mingjing Feng; Chen Sheng; Yinhua Wang; Wenya Cao
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.