Xianghui Huang1,2, Deyi Zhuang3,4, Ling Liu5, Wanting Li6, Jungang Liu7, Zhongxi Zhang6.
Abstract
A fractured catheter in the posterior auricular vein is exceedingly rare. Imaging revealed that it was migrating freely and currently overlapped the temporal bone. With multidisciplinary cooperation, general anesthesia, and three-dimensional computed tomography (3D-CT) for guidance, the catheter was removed uneventfully.Keywords: 3D-CT; Auricular vein; Catheter
Mesh:
Year: 2020 PMID: 31970474 DOI: 10.1007/s00381-020-04513-w