| Literature DB >> 31967220 |
Luciana Vieira1,2, Lara Patrícia Bastos Rocha1,3, Sunita Mathur4, Larissa Santana4, Priscilla Flávia de Melo1, Vinicius Zacarias Maldaner da Silva1, João Luiz Quaglioti Durigan1, Gerson Cipriano1,5.
Abstract
OBJECTIVE: To evaluate the safety and feasibility of the ultrasound assessment of quadriceps in the emergency setting. To assess the intra- and interrater reliability for the acquisition and analysis of ultrasound images of muscle thickness and echogenicity in critically ill trauma patients between health professionals with different levels of expertise.Entities:
Mesh:
Year: 2019 PMID: 31967220 PMCID: PMC7008982 DOI: 10.5935/0103-507X.20190072
Source DB: PubMed Journal: Rev Bras Ter Intensiva ISSN: 0103-507X
Figure 1Example of image processing to measure muscle thickness. The dotted line represents total quadriceps thickness on panel (A) and rectus femoris thickness on panel (B).
Figure 2Example of image processing to measure muscle echogenicity. The selected area represents the region of interest, using (A) the square method or (B) the trace method; the grayscale is defined by the histogram below each image.
Demographic and clinical characteristics of the study sample
| Characteristics | Acquisition | Analysis |
|---|---|---|
| Age (years) | 35.4 ± 12.5 | 37.1 ± 13.4 |
| Male sex | 8 (80) | 8 (80) |
| APACHE II score | 15.8 ± 3.3 | 16.2 ± 2.7 |
| BMI (kg/m2) | 25.7 ± 8.3 | 24.9 ± 6.8 |
| Injury severity score | 38.5 ± 18.0 | 39.4 ± 15.3 |
| Sepsis | 7 (70) | 6 (60) |
| Septic shock | 3 (30) | 4 (40) |
| Multiorgan failure | 3 (30) | 4 (40) |
APACHE - Acute Physiologic and Chronic Health Evaluation; BMI - body mass index. p > 0.05 for all comparisons between groups. Results expressed as the mean ± standard deviation or n (%).
Intrarater reliability for three acquired or analyzed images of muscle thickness and echogenicity by assessor
| Parameter | Expert | Novice |
|---|---|---|
| Acquisition (n = 10) | ||
| Thickness - quadriceps (cm) | 0.952 (0.821 - 0.988) | 0.999 (0.998 - 1.000) |
| Thickness - | 0.999 (0.997 - 1.000) | 0.997 (0.988 - 0.999) |
| Echogenicity - square (AU) | 1.000 (0.999 - 1.000) | 0.996 (0.984 - 0.999) |
| Echogenicity - trace (AU) | 0.999 (0.995 - 1.000) | 0.987 (0.949 - 0.997) |
| Analysis (n = 10) | ||
| Thickness - quadriceps (cm) | 0.999 (0.996 - 1.000) | 1.000 (0.999 - 1.000) |
| Thickness - | 0.998 (0.994 - 1.000) | 0.998 (0.992 - 1.000) |
| Echogenicity - square (AU) | 0.999 (0.998 - 1.000) | 0.997 (0.989 - 0.999) |
| Echogenicity - trace (AU) | 0.999 (0.997 - 1.000) | 0.988 (0.954 -0.997) |
AU - arbitrary units. Results expressed as the intraclass correlation coefficients (95% confidence interval).
Interrater reliability for image acquisition and analysis of muscle thickness and echogenicity
| Parameter | ICC | SEM | CV |
|---|---|---|---|
| Acquisition (n = 10) | |||
| Thickness - quadriceps (cm) | 0.990 (0.970 - 0.997) | 0.06 | 2.55 |
| Thickness - | 0.990 (0.964 - 0.997) | 0.04 | 5.69 |
| Echogenicity - square (AU) | 0.996 (0.986 - 0.999) | 1.73 | 1.29 |
| Echogenicity - trace (AU) | 0.977 (0.934 - 0.994) | 0.75 | 2.31 |
| Analysis (n = 10) | |||
| Thickness - quadriceps (cm) | 0.999 (0.997 - 1.000) | 0.02 | 1.55 |
| Thickness - | 0.999 (0.997 - 1.000) | 0.01 | 4.57 |
| Echogenicity - square (AU) | 0.994 (0.968 - 0.999) | 2.04 | 2.54 |
| Echogenicity - trace (AU) | 0.961 (0.894 - 0.989) | 1.02 | 3.99 |
ICC - intraclass correlation coefficient; SEM - standard error of the measurement; CV - coefficient variation; AU - arbitrary units. Data are presented as intraclass correlation coefficients (95% confidence intervals) or %.
Absolute values of muscle thickness and echogenicity for acquisition and analysis by two assessors with different levels of expertise.
| Parameter | Expert | Novice | p value |
|---|---|---|---|
| Acquisition (n = 10) | |||
| Thickness - quadriceps (cm) | 3.43 ± 0.87 | 3.47 ± 0.84 | 0.97 |
| Thickness - | 1.86 ± 0.55 | 1.82 ± 0.52 | 0.96 |
| Echogenicity - square (AU) | 77.4 ± 16.8 | 76.4 ± 16.7 | 0.98 |
| Echogenicity - trace (AU) | 69.1 ± 12.7 | 67.5 ± 16.1 | 0.94 |
| Analysis (n = 10) | |||
| Thickness - quadriceps (cm) | 3.18 ± 0.85 | 3.16 ± 0.88 | 0.99 |
| Thickness - | 1.67 ± 0.48 | 1.72 ± 0.50 | 0.98 |
| Echogenicity - square (AU) | 83.9 ± 18.6 | 81.8 ± 17.6 | 0.96 |
| Echogenicity - trace (AU) | 67.7 ± 14.6 | 65.1 ± 14.4 | 0.94 |
AU - arbitrary units. A between-measures analysis of variance was used to test for significant differences between assessors and techniques; no significant differences were found for muscle thickness or echogenicity between assessors with different levels of expertise or between techniques for muscle thickness; however, echogenicity was significantly higher when quantified by the square technique compared to the tracing technique, for both acquisition and analysis (p < 0.001). Results expressed as the mean ± standard deviation.
Figure 3Bland-Altman plots using for concordance of the inter-rater evaluations between the evaluation of the echo square and echo traced.
95%CI - 95% confidence interval.
Figure 4Bland-Altman plots for the concordance of the interrater evaluations of the thickness rectus femoris vastus intermedius and thickness rectus femoris.
RF - rectus femoris. VI - vastus intermedius.