Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans.

Panos Papaspyridakos1, Yo-Wei Chen2, Bahaa Alshawaf3, Kiho Kang4, Matthew Finkelman5, Vasilios Chronopoulos6, Hans-Peter Weber7.   

Abstract

STATEMENT OF PROBLEM: Data on the accuracy of printed casts from complete-arch digital implant scans are lacking.
PURPOSE: The purpose of this in vitro study was to compare the 3D accuracy of printed casts from a complete-arch digital implant intraoral scan with stone casts from conventional impressions.
MATERIAL AND METHODS: An edentulous mandibular cast with 4 multiunit abutments with adequate anteroposterior spread was used as the master cast. Digital scans (n=25) were made by using a white light intraoral scanner (IOS). The generated standard tessellation language (STL) data sets were imported into a computer-assisted design (CAD) software program to generate complete-arch implant casts through 3D printing technology. The 25 printed casts and the mandibular master cast were further digitized by using a laboratory reference scanner (Activity 880; Smart Optics). These STL data sets were superimposed on the digitized master cast in a metrology software program (Geomagic Control X) for virtual analysis. The root mean square (RMS) error and the average offset were measured.
RESULTS: When compared with the master cast, the printed casts had a mean ±standard deviation RMS error of 59 ±16 μm (95% CI: 53, 66). The maximum RMS error reached 98 μm. The average offsets were all negative, with a significant difference compared with zero (P<.001).
CONCLUSIONS: The implant 3D deviations of the printed casts from complete-arch digital scans had statistically significant differences compared with those of the master cast but may still be within the acceptable range for clinical application.
Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Year:  2020        PMID: 31959396     DOI: 10.1016/j.prosdent.2019.10.029

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

Review 2.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 3.  The Modern and Digital Transformation of Oral Health Care: A Mini Review.

Authors:  Muhammad Syafiq Alauddin; Ahmad Syukran Baharuddin; Mohd Ifwat Mohd Ghazali
Journal:  Healthcare (Basel)       Date:  2021-01-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.