Literature DB >> 3195813

Lung volume maintenance prevents lung injury during high frequency oscillatory ventilation in surfactant-deficient rabbits.

P R McCulloch1, P G Forkert, A B Froese.   

Abstract

Controversy exists whether high frequency oscillatory ventilation with an active expiratory phase (HFO-A) should be used at low ventilator pressures or high alveolar volumes to minimize lung injury in the atelectasis-prone lung. We therefore ventilated 20 anesthetized, tracheostomized rabbits made surfactant-deficient by lung lavage in 1 of 3 ways: HFO-A at a high lung volume (HFO-A/HI), HFO-A at a low lung volume (HFO-A/LO), or conventional mechanical ventilation (CMV); all received 100% oxygen for 7 h. We examined oxygenation, lung mechanics, and lung pathology. Arterial oxygenation in the HFO-A/HI rabbits was kept greater than 350 mm Hg. Mean lung volume above FRC in these animals was 23.4 ml/kg. In rabbits ventilated with HFO-A/LO and CMV, arterial oxygen tensions were 70 to 100 mm Hg. Mean lung volumes were 7.8 and 4.3 ml/kg, respectively. Total respiratory system pressure-volume curves (P-V curves) showed no change from baseline in the HFO-A/HI group after 7 h of ventilation. The low lung volume groups (HFO-A/LO and CMV) showed a diminution in hysteresis of their P-V curves, lower total respiratory system compliance, more hyaline membranes and severe airway epithelial damage. (All changes significant with p less than 0.05). We conclude that maintenance of alveolar volume is a key mechanism in the prevention of lung injury during mechanical ventilation of the atelectasis-prone lung. For optimal outcome using high frequency oscillatory ventilation, alveoli must be actively reexpanded and then kept expanded using appropriate mean airway pressures.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3195813     DOI: 10.1164/ajrccm/137.5.1185

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  53 in total

1.  Effect of changes in oscillatory amplitude on PaCO(2) and PaO(2) during high frequency oscillatory ventilation.

Authors:  C Morgan; P R Dear; S J Newell
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-05       Impact factor: 5.747

2.  Meta-analysis of elective high frequency ventilation in preterm infants with respiratory distress syndrome.

Authors:  F Cools; M Offringa
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-01       Impact factor: 5.747

Review 3.  Update on modalities of mechanical ventilators.

Authors:  A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

Review 4.  The pulmonary physician in critical care * 7: ventilator induced lung injury.

Authors:  T Whitehead; A S Slutsky
Journal:  Thorax       Date:  2002-07       Impact factor: 9.139

5.  Early use of high frequency ventilation in the premature neonate.

Authors:  Patrick Van Reempts; Christel Borstlap; Sabine Laroche; Jean-Claude Van der Auwera
Journal:  Eur J Pediatr       Date:  2003-02-04       Impact factor: 3.183

6.  Static pressure-volume curve characteristics are moderate estimators of optimal airway pressures in a mathematical model of (primary/pulmonary) acute respiratory distress syndrome.

Authors:  Dick G Markhorst; Huibert R van Genderingen; Adrianus J van Vught
Journal:  Intensive Care Med       Date:  2004-09-15       Impact factor: 17.440

7.  Standardized lung recruitment during high frequency and conventional ventilation: similar pathophysiologic and inflammatory responses in an animal model of respiratory distress syndrome.

Authors:  Ramesh K M Krishnan; Pat A Meyers; Cathy Worwa; Ronald Goertz; Galen Schauer; Mark C Mammel
Journal:  Intensive Care Med       Date:  2004-03-02       Impact factor: 17.440

Review 8.  Did studies on HFOV fail to improve ARDS survival because they did not decrease VILI? On the potential validity of a physiological concept enounced several decades ago.

Authors:  Didier Dreyfuss; Jean-Damien Ricard; Stéphane Gaudry
Journal:  Intensive Care Med       Date:  2015-10-05       Impact factor: 17.440

Review 9.  Closing volume: a reappraisal (1967-2007).

Authors:  Joseph Milic-Emili; Roberto Torchio; Edgardo D'Angelo
Journal:  Eur J Appl Physiol       Date:  2007-01-20       Impact factor: 3.078

10.  Airway pressure and transpulmonary pressure during high-frequency oscillation for acute respiratory distress syndrome.

Authors:  William R Henderson; Paolo B Dominelli; Donald E G Griesdale; Daniel Talmor; A William Sheel
Journal:  Can Respir J       Date:  2013-10-17       Impact factor: 2.409