Literature DB >> 31955940

Ultralong Versus Standard Long Peripheral Intravenous Catheters: A Randomized Controlled Trial of Ultrasonographically Guided Catheter Survival.

Amit Bahl1, Mahmoud Hijazi2, Nai-Wei Chen3, Ludovic Lachapelle-Clavette2, Jacob Price2.   

Abstract

STUDY
OBJECTIVE: Ultrasonographically guided intravenous peripheral catheters have dismal dwell time, with most intravenous lines failing before completion of therapy. Catheter length in the vein is directly related to catheter longevity. We investigate the survival of an ultralong ultrasonographically guided intravenous peripheral catheter compared with a standard long one.
METHODS: We conducted a single-site, nonblinded, randomized trial of catheter survival. Adult patients presenting to the emergency department with difficult vascular access were recruited and randomized to receive either standard long, 4.78-cm, 20-gauge ultrasonographically guided intravenous peripheral catheters or ultralong, 6.35-cm, 20-gauge ultrasonographically guided intravenous peripheral catheters. The primary outcome was duration of catheter survival. The secondary outcome was the optimal length of the catheter in the vein to maximize survival. Additional intravenous-related endpoints included first-stick success, time to insertion, number of attempts, thrombosis, and infection.
RESULTS: Between October 2018 and March 2019, 257 patients were randomized, with 126 in the standard long ultrasonographically guided intravenous peripheral catheter group and 131 in the ultralong group. Kaplan-Meier estimate of catheter median survival time in the ultralong group was 136 hours (95% confidence interval [CI] 116 to 311 hours) compared with 92 hours (95% CI 71 to 120 hours) in the standard long group, for a difference of 44 hours (95% CI 2 to 218 hours). The optimal catheter length in the vein was 2.75 cm, and intravenous lines with greater than 2.75 cm inserted had a median survival of 129 hours (95% CI 102 to 202 hours) compared with 75 hours (95% CI 52 to 116 hours) for intravenous lines with less than or equal to 2.75 cm, for a difference of 54 hours (95% CI 10 to 134 hours). Insertion characteristics were similar between the groups: 74.1% versus 79.4% first-stick success (95% CI for the difference -2% to 5%), 1.4 versus 1.3 for number of attempts (95% CI for the difference -0.1 to 0.3), and 6.9 versus 5.9 minutes to completion (95% CI for the difference -1.3 to 3.4) with ultralong versus standard long, respectively. There were no cases of infection or thrombosis.
CONCLUSION: This study demonstrated increased catheter survival when the ultralong compared with the standard long ultrasonographically guided intravenous peripheral catheter was used, whereas insertion characteristics and safety appeared similar.
Copyright © 2019 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 31955940     DOI: 10.1016/j.annemergmed.2019.11.013

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  2 in total

1.  Vesicant infusates are not associated with ultrasound-guided peripheral intravenous catheter failure: A secondary analysis of existing data.

Authors:  Amit Bahl; Mahmoud Hijazi; Nai-Wei Chen
Journal:  PLoS One       Date:  2022-01-27       Impact factor: 3.240

Review 2.  Ultrasound-guided peripheral vascular catheterization in pediatric patients: a narrative review.

Authors:  Yoshinobu Nakayama; Jun Takeshita; Yasufumi Nakajima; Nobuaki Shime
Journal:  Crit Care       Date:  2020-09-30       Impact factor: 9.097

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.