Literature DB >> 31955842

A new sensitive method for the simultaneous chromatographic separation and tandem mass spectrometry detection of anticoccidials, including highly polar compounds, in environmental waters.

D Mooney1, C Coxon2, K G Richards3, L W Gill4, P-E Mellander5, M Danaher6.   

Abstract

A sensitive and selective method was developed and validated for the determination of 26 anticoccidial compounds (six ionophores and twenty chemical coccidiostats) in surface and groundwater samples at parts-per-quadrillion (pg L-1) to parts-per-trillion (ng L-1) levels by ultra-high performance liquid chromatography with tandem mass spectrometry detection (UHPLC-MS/MS). A range of different analytical columns and mobile phase compositions were evaluated to enhance selectivity and retention of a number of highly polar and basic anticoccidials along with other non-polar coccidiostats. A combined separation, including these problematic polar compounds, was achieved on a phenyl-hexyl column, by binary gradient elution with water/acetonitrile using ammonium formate and formic acid as additives. The anticoccidial residues were extracted from raw, unfiltered, water samples (250 mL) using polymeric divinylbenzene solid phase extraction (SPE) cartridges, with subsequent elution (methanol:acetonitrile:ethyl acetate, 40:40:20, v/v) and concentration prior to determination. The method recovery (at a concentration representative of realistic expected environmental water concentrations based on literature review) ranged from 81% to 105%. The method was successfully validated for 26 anticoccidials, at four concentration levels, in accordance to Commission Decision 2002/657/EC and SANTE/11813/2017 guidelines. Trueness and precision, under within-laboratory reproducibility conditions, ranged from 88% to 111% and 0.9% to 10.3% respectively.
Copyright © 2020. Published by Elsevier B.V.

Entities:  

Keywords:  Chemical coccidiostats; Environmental water; Ionophores; SPE; UHPLC–MS/MS

Mesh:

Substances:

Year:  2020        PMID: 31955842     DOI: 10.1016/j.chroma.2020.460857

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

Review 1.  Tandem mass spectrometry of small-molecule antiviral drugs: 3. antiviral agents against herpes, influenza and other viral infections.

Authors:  W M A Niessen
Journal:  Int J Mass Spectrom       Date:  2020-06-13       Impact factor: 1.986

2.  Pharmacokinetics of Nafamostat, a Potent Serine Protease Inhibitor, by a Novel LC-MS/MS Analysis.

Authors:  Hyeon Seok Oh; Taehyung Kim; Dong-Hyeon Gu; Tae Suk Lee; Tae Hwan Kim; Soyoung Shin; Beom Soo Shin
Journal:  Molecules       Date:  2022-03-14       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.