| Literature DB >> 3195498 |
N S Torké1, P S Mehta, R M Vohra, A R Patel, P C Shah.
Abstract
Cation-exchange chromatography gives falsely decreased values for glycosylated hemoglobins (GHbs) in patients with abnormal hemoglobins (Hbs) such as S, D, G, C, E, and O. This decrease is thought to be proportional to the percentage of abnormal Hb present. In the authors' study, cation-exchange column chromatographic GHb values on 84 nondiabetic patients heterozygous for Hb S, 28 AS diabetic patients, and 23 nondiabetic patients heterozygous for Hb C were calculated to account for the percentage of abnormal Hb, and the resulting values were compared with the GHb values obtained by high-performance liquid chromatography (HPLC). There existed a good correlation between the calculated GHb and the GHb obtained by HPLC (r = 0.92 for AS and r = 0.94 for AC). In patients with elevated Hb F, chromatographic GHb values are falsely high. In such cases, correction can be made by subtracting the Hb F value from the observed GHb. In laboratories where cation exchange chromatography is used, accurate determination of GHb can be made by adjusting observed values for portion of the abnormal Hb present.Entities:
Mesh:
Substances:
Year: 1988 PMID: 3195498 DOI: 10.1093/ajcp/90.6.697
Source DB: PubMed Journal: Am J Clin Pathol ISSN: 0002-9173 Impact factor: 2.493