Literature DB >> 31954749

Insulin pumps use in Greece: Efficacy and safety data from 140 patients with type 1 diabetes mellitus.

Maria Somali1, Stavroula A Paschou2, Zadalla Mouslech3.   

Abstract

OBJECTIVE: The aim of this study was to investigate the efficacy and safety of continuous subcutaneous insulin infusion (CSII) regarding glycaemic control and quality of life in patients with type 1 diabetes mellitus (T1DM), who were previously treated with multiple daily injections (MDI). PATIENTS AND METHODS: 140 patients with T1DM [mean age 33.7 ± 22.1 years; 54 males, 76 females, 10 children; duration of diabetes 19.1 ± 8.4 years; total daily insulin usage while on MDI (IU/day) 57.86 ± 15.32; HbA1c at the beginning of CSII treatment 8.67 ± 1.54%] were included in the study. HbA1c, glucose levels, BMI, severe hypoglycemic and diabetic ketoacidosis (DKA) episodes were recorded and compared to the data prior to CSII introduction. The evaluation of the quality of life was assessed with a self-questionnaire adjusted from the SF-12 and diabetes quality of life (DQoL) questionnaires.
RESULTS: HbA1c was reduced from 8.67 ± 1.54 to 6.85 ± 0.52% (p < 0.001). This reduction was independent of age, gender, body mass index (BMI) and diabetes duration. Daily insulin requirements were lower at the end of the follow-up (36.40 ± 12.20 IU/day) compared with the needs during enrolment (57.86 ± 15.32 IU/day) (p < 0.001). BMI presented no significant alterations. Ten (10) severe hypoglycemic episodes were recorded but the overall rate was decreased by 71.5% (p < 0.001). Only 3 cases of ketoacidosis were recorded. Quality of life parameters were remarkably improved.
CONCLUSIONS: This study provided evidence that CSII treatment was superior to MDI for patients with T1DM in Greece. CSII offered a safe, effective alternative to MDI, while improving glycaemic control, side-effects and quality of life.
Copyright © 2020. Published by Elsevier B.V.

Entities:  

Keywords:  CSII; Continuous subcutaneous insulin infusion; Insulin pump therapy; MDI; Multiple daily injection; Type 1 diabetes

Year:  2020        PMID: 31954749     DOI: 10.1016/j.diabres.2020.108026

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  2 in total

1.  The diabetes quality of life brief clinical inventory in combination with the management strategies in type 1 diabetes mellitus with or without the use of insulin pump.

Authors:  Emmanouil S Benioudakis; Evangelos D Georgiou; Eirini D Barouxi; Athanasios M Armagos; Vaia Koutsoumani; Faidra Anastasiou-Veneti; Eleni Koutsoumani; Maria Brokalaki
Journal:  Diabetol Int       Date:  2020-11-16

2.  Predictors of the effectiveness of insulin pumps in patients with type 1 diabetes mellitus.

Authors:  Joana Camões Neves; João Sérgio Neves; Celestino Neves; Davide Carvalho
Journal:  Endocrine       Date:  2021-08-02       Impact factor: 3.633

  2 in total