Literature DB >> 31948666

Comparison of Holter With Zio Patch Electrocardiography Monitoring in Children.

Meena Bolourchi1, Eric S Silver1, David Muwanga1, Esteban Mendez1, Leonardo Liberman2.   

Abstract

The standard for ambulatory arrhythmia detection in children is the Holter monitor. The Zio XT (Zio) patch has been FDA-approved for use in adults. However, its utility in children has not been directly compared with the Holter. We studied the ability to detect arrhythmias and patient comfort of the Zio versus the Holter in children. Patients <22 years old were prospectively enrolled to wear the Holter and Zio simultaneously for 48 hours at our institution. Detection of clinically significant arrhythmias was compared using McNemar's test. Wear-time and artifact time was compared using Wilcoxon sign test. Patient satisfaction ratings were analyzed with paired t tests. Two hundred patients (57% male) were included for analysis. The median age was 13.5 years (range 23 days to 21.7 years), and 40% had heart disease. The Zio and Holter had comparable median wear-times, 48.2 hours (interquartile range [IQR] 45.8 to 50.2]) versus 48.0 (48.0 to 48.0), respectively, p = 0.14, but the Zio had less artifact than the Holter, 2.8% (IQR 1.1 to 8.6) versus 5.6% (2.4 to 15.7), respectively, p <0.001. There was no difference in detection of clinically significant arrhythmias for the Zio versus the Holter (p = 0.23), however 75% of patients preferred the Zio over the Holter (p <0.001) due to lack of wires and the ability to shower. In conclusion, the Zio patch is as good as the Holter monitor in detection of clinically significant arrhythmias in children with less artifact. Patients/parents more often preferred the Zio over the Holter.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 31948666     DOI: 10.1016/j.amjcard.2019.11.028

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Ambulatory Cardiac Monitoring in Infants with Supraventricular Tachycardia.

Authors:  Nicolas M Hidalgo Corral; Olga Witkowska; Magdalena Ślusarczyk; Marek Dziubiński; Bradley C Clark
Journal:  Pediatr Cardiol       Date:  2022-05-15       Impact factor: 1.838

2.  The utility of patch recorders in neonatal ambulatory electrocardiogram recording.

Authors:  Mani Ram Krishna; Usha Nandhini Sennaiyan; K Ramanathan
Journal:  Indian Pacing Electrophysiol J       Date:  2020-12-19

3.  Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series.

Authors:  Srinivasan Murali; Nicolas Brugger; Francisco Rincon; Manoj Mashru; Stéphane Cook; Jean-Jacques Goy
Journal:  Front Cardiovasc Med       Date:  2020-11-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.