Literature DB >> 31947243

Real-time Subject-specific Head and Facial Mimic Animation System using a Contactless Kinect Sensor and System of Systems Approach.

T N Nguyen, S Dakpe, M C Ho Ba Tho, T T Dao.   

Abstract

Facial palsies due to stroke, accidental and sportive injuries or sometimes without etiology, affect the professional and personal lives of involved patients. These disorders are not only a functional handicap but also a social integration impairment. The recovery of facial mimics with a normal and symmetrical facial expression allows involved patients to improve their living conditions and social identity. Current approaches lack of visual feedbacks. To monitor facial mimics and head movements in a quantitative and objective manners, a computer-aided animation system needs to be developed. Numerous systems have been proposed using single camera, stereo camera, 3-D scanner, and Kinect approaches. In particular, Kinect contactless sensor has been proven to be very suitable for 3-D facial simulation applications. However, little studies have employed the Kinect sensor for real-time head animation applications. Consequently, this study developed a real-time head and facial mimic animation system using the contactless Kinect sensor and the system of systems approach. To evaluate the accuracy of the subject-specific Kinect-based geometrical models, magnetic resonance imaging (MRI) data were used. As results, the mean distance deviation between generated Kinect-based and reconstructed MRI-based geometrical head models are approximately 1 mm for two tested subjects. The generation times are 9.7 s ± 0.3 and 0.046 s ± 0.005 by using the full facial landmarks and MPEG-4 facial landmarks respectively. Real-time head and facial mimic animations were illustrated. Particularly, the system could be executed at a very high framerate (60 fps). Further developments relate to the integration of texture information and internal structures such as a skull and muscle network to develop a full subject specific head and facial mimic animation system for facial mimic rehabilitation.

Entities:  

Mesh:

Year:  2019        PMID: 31947243     DOI: 10.1109/EMBC.2019.8856606

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  1 in total

1.  Development and clinical evaluation of a contactless operating interface for three-dimensional image-guided navigation for endovascular neurosurgery.

Authors:  Masahiro Nishihori; Takashi Izumi; Yoshitaka Nagano; Masaki Sato; Tetsuya Tsukada; Asuka Elisabeth Kropp; Toshihiko Wakabayashi
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-03-11       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.