Literature DB >> 31946571

Dual-Stiffness Force-Sensing Cannulation Tool for Retinal Microsurgery.

Changyan He, Emily Yang, Iulian Iordachita.   

Abstract

Retinal vein cannulation is a promising treatment for retinal vein occlusion that involves the injection of an anticoagulant directly into the occluded vein to dissolve the blockage. However, excessive forces applied by the injection tool during the procedure, at either the scleral incision or injection site, can result in injury to the eye. Furthermore, the force required to puncture retinal veins (around 10 mN) is well below human sensing ability and an order of magnitude smaller than those that can be safely applied at the sclera (around 100 mN). Detection and management of tool-to-tissue forces on these different scales are some of the most challenging aspects of the cannulation procedure. This work describes the development of a sensorized cannulation tool capable of detecting both tool-to-vein puncture forces and tool-to-sclera contact forces. By combining two materials, nitinol alloy for the tool tip and stainless steel for the tool shaft, to achieve dual stiffness, the tool possesses a flexible tip to capture small vein puncture forces and a stiffer shaft to maintain straightness during use. Three segments of fiber Bragg grating sensors are calibrated to measure the transverse forces at both the tool tip and sclerotomy, as well as to determine the tool insertion depth within the eye. The results of the validation experiments show that the root mean square error of the measurements for the force at the tip, the force at the sclerotomy, and the tool position are 0.70 mN, 1.59 mN, and 0.69 mm, respectively.

Entities:  

Mesh:

Year:  2019        PMID: 31946571      PMCID: PMC7260694          DOI: 10.1109/EMBC.2019.8857739

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  2 in total

Review 1.  CARS 2018-Computer Assisted Radiology and Surgery Proceedings of the 32nd International Congress and Exhibition Berlin, Germany, June 20-23, 2018.

Authors: 
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06       Impact factor: 2.924

2.  The prevalence of retinal vein occlusion: pooled data from population studies from the United States, Europe, Asia, and Australia.

Authors:  Sophie Rogers; Rachel L McIntosh; Ning Cheung; Lyndell Lim; Jie Jin Wang; Paul Mitchell; Jonathan W Kowalski; Hiep Nguyen; Tien Y Wong
Journal:  Ophthalmology       Date:  2010-02       Impact factor: 12.079

  2 in total
  1 in total

1.  An automatic drug injection device with spatial micro-force perception guided by an microscopic image for robot-assisted ophthalmic surgery.

Authors:  Zhen Li; Pan Fu; Bing-Ting Wei; Jie Wang; An-Long Li; Ming-Jun Li; Gui-Bin Bian
Journal:  Front Robot AI       Date:  2022-08-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.