Literature DB >> 31946564

Infection Screening System Using Thermography and CCD Camera with Good Stability and Swiftness for Non-contact Vital-Signs Measurement by Feature Matching and MUSIC Algorithm.

Toshiaki Negishi, Guanghao Sun, Shohei Sato, He Liu, Takemi Matsui, Shigeto Abe, Hidekazu Nishimura, Tetsuo Kirimoto.   

Abstract

Screening systems for infectious diseases based on fever have been implemented at international airports to prevent the spread of infection for over a decade. Currently, only Infrared Thermography (IRT) is used for screening and measuring facial skin temperature, which is one of clinical indicators of potential infection. Aiming at higher accuracy in screening, our group adopted heart rate (HR) and respiration rate (RR) for the first time as the new screening parameters. In our previous study, we proposed a screening system based on dual image sensors, which include IRT and a charged-coupled devices (CCD) camera. The sensors can measure three vital signs simultaneously, namely HR, RR, and facial skin temperature. For the measurement of RR in this system, stability and swiftness must be applied for application in airports. In this study, we introduce feature matching and multiple signal classification (MUSIC) algorithm in this system. Feature matching between thermal images and RGB images captured by a CCD camera and IRT, respectively, is used to detect the nose and mouth in IRT, which helps extract respiration signals corresponding to airflow from breathing. In addition, the MUSIC algorithm improves the accuracy of RR frequency estimations in limited time respiration signal and achieves swiftness. The proposed method improves stability by simultaneously detecting the nose and mouth in thermal images, and enhances the accuracy of estimated RR using the MUSIC algorithm. By using this system, we evaluate the accuracy of the estimated vital signs. The performance of this screening system was evaluated using data obtained from 12 influenza patients and 13 healthy subjects at a clinical facility in Fukushima, Japan.

Entities:  

Mesh:

Year:  2019        PMID: 31946564     DOI: 10.1109/EMBC.2019.8857027

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

Review 1.  Review of the efficacy of infrared thermography for screening infectious diseases with applications to COVID-19.

Authors:  Kosar Khaksari; Thien Nguyen; Brian Hill; Timothy Quang; John Perreault; Viswanath Gorti; Ravi Malpani; Emily Blick; Tomás González Cano; Babak Shadgan; Amir H Gandjbakhche
Journal:  J Med Imaging (Bellingham)       Date:  2021-03-25

Review 2.  Implementation of Thermal Camera for Non-Contact Physiological Measurement: A Systematic Review.

Authors:  Martin Clinton Tosima Manullang; Yuan-Hsiang Lin; Sheng-Jie Lai; Nai-Kuan Chou
Journal:  Sensors (Basel)       Date:  2021-11-23       Impact factor: 3.576

3.  Contactless Vital Signs Measurement System Using RGB-Thermal Image Sensors and Its Clinical Screening Test on Patients with Seasonal Influenza.

Authors:  Toshiaki Negishi; Shigeto Abe; Takemi Matsui; He Liu; Masaki Kurosawa; Tetsuo Kirimoto; Guanghao Sun
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

4.  A non-contact infection screening system using medical radar and Linux-embedded FPGA: Implementation and preliminary validation.

Authors:  Cuong V Nguyen; Truong Le Quang; Trung Nguyen Vu; Hoi Le Thi; Kinh Nguyen Van; Thanh Han Trong; Tuan Do Trong; Guanghao Sun; Koichiro Ishibashi
Journal:  Inform Med Unlocked       Date:  2019-08-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.