Literature DB >> 31946435

Automatic Artifact Detection in Impedance Cardiogram Using Pulse Similarity Index.

Mohamad Forouzanfar, Fiona C Baker, Ian M Colrain, Massimiliano de Zambotti.   

Abstract

Impedance cardiography (ICG) is a noninvasive technique for evaluation of cardiac hemodynamic parameters such as cardiac output and pre-ejection period. However, the sensitivity of the technique to motion artifact, electrode displacement, and cardiovascular pathologies can severely impact the accuracy of hemodynamic parameter estimates. In this paper, we proposed a new algorithm for the automatic detection and exclusion of corrupted ICG cardiac cycles by defining a pulse similarity index that quantifies the level of pulse corruption and its diversion from a typical-shaped pulse. The index considers different features (activity, structure, shape, and pattern) of the ICG cardiac cycles. The algorithm is compared on sleep data collected from 20 participants against expert identified corrupted cycles. The artifact rejection algorithm achieved a high accuracy of 96% in detection of expert-identified corrupted ICG cycles, including those with normal amplitude as well as out-of-range values, and was robust to different types and levels of artifact. The algorithm shows promise toward applications requiring accurate and reliable automatic measurement of cardiac hemodynamic parameters from prolonged data sets.

Entities:  

Year:  2019        PMID: 31946435     DOI: 10.1109/EMBC.2019.8856542

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Validation of a new impedance cardiography analysis algorithm for clinical classification of stress states.

Authors:  Shafa-At Ali Sheikh; Nil Z Gurel; Shishir Gupta; Ikenna V Chukwu; Oleksiy Levantsevych; Mhmtjamil Alkhalaf; Majd Soudan; Rami Abdulbaki; Ammer Haffar; Gari D Clifford; Omer T Inan; Amit J Shah
Journal:  Psychophysiology       Date:  2022-02-12       Impact factor: 4.348

2.  Impact of evening alcohol consumption on nocturnal autonomic and cardiovascular function in adult men and women: a dose-response laboratory investigation.

Authors:  Massimiliano de Zambotti; Mohamad Forouzanfar; Harold Javitz; Aimee Goldstone; Stephanie Claudatos; Vanessa Alschuler; Fiona C Baker; Ian M Colrain
Journal:  Sleep       Date:  2021-01-21       Impact factor: 5.849

3.  An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis.

Authors:  Shafa-At Ali Sheikh; Amit Shah; Oleksiy Levantsevych; Majd Soudan; Jamil Alkhalaf; Ali Bahrami Rad; Omer T Inan; Gari D Clifford
Journal:  Physiol Meas       Date:  2020-08-11       Impact factor: 2.688