BACKGROUND: The risks of ventricular fibrillation (Vfib) associated with frequency-domain optical coherence tomography (OCT)/optical frequency domain imaging (OFDI) remain undetermined.Methods and Results: We retrospectively studied the occurrence of Vfib during OCT/OFDI for unselected indications. The frequency of Vfib and patient and procedural characteristics were investigated. A total of 4,467 OCT/OFDI pullback examinations were performed in 1,754 patients (median of 2.0 [2.0-3.0] pullbacks for 1.0 [1.0-1.3] vessels). OCT/OFDI was performed during PCI in 899 patients (51.3%). The contrast injection volume per pullback was 14.4 (11.7-17.2) mL with a flow rate of 3.4 (3.2-3.5) mL/s. Vfib occurred in 31 pullbacks (0.69%) in 30 patients (1.7%). No cases of Vfib occurred when using low-molecular-weight dextran. On multivariate analysis, contrast volume was the only independent factor for predicting Vfib (odds ratio, 1.080; 95% confidence interval, 1.008-1.158, P=0.029). The best cutoff value of contrast volume for predicting Vfib was 19.2 mL (area under the curve, 0.713, P<0.001; diagnostic accuracy, 87.1%). CONCLUSIONS: The present large, single-center registry study indicated that Vfib during OCT/OFDI was rare for unselected indications. Contrast injection volume used to displace blood should be limited to avoid Vfib.
BACKGROUND: The risks of ventricular fibrillation (Vfib) associated with frequency-domain optical coherence tomography (OCT)/optical frequency domain imaging (OFDI) remain undetermined.Methods and Results: We retrospectively studied the occurrence of Vfib during OCT/OFDI for unselected indications. The frequency of Vfib and patient and procedural characteristics were investigated. A total of 4,467 OCT/OFDI pullback examinations were performed in 1,754 patients (median of 2.0 [2.0-3.0] pullbacks for 1.0 [1.0-1.3] vessels). OCT/OFDI was performed during PCI in 899 patients (51.3%). The contrast injection volume per pullback was 14.4 (11.7-17.2) mL with a flow rate of 3.4 (3.2-3.5) mL/s. Vfib occurred in 31 pullbacks (0.69%) in 30 patients (1.7%). No cases of Vfib occurred when using low-molecular-weight dextran. On multivariate analysis, contrast volume was the only independent factor for predicting Vfib (odds ratio, 1.080; 95% confidence interval, 1.008-1.158, P=0.029). The best cutoff value of contrast volume for predicting Vfib was 19.2 mL (area under the curve, 0.713, P<0.001; diagnostic accuracy, 87.1%). CONCLUSIONS: The present large, single-center registry study indicated that Vfib during OCT/OFDI was rare for unselected indications. Contrast injection volume used to displace blood should be limited to avoid Vfib.
Authors: Makoto Araki; Seung-Jung Park; Harold L Dauerman; Shiro Uemura; Jung-Sun Kim; Carlo Di Mario; Thomas W Johnson; Giulio Guagliumi; Adnan Kastrati; Michael Joner; Niels Ramsing Holm; Fernando Alfonso; William Wijns; Tom Adriaenssens; Holger Nef; Gilles Rioufol; Nicolas Amabile; Geraud Souteyrand; Nicolas Meneveau; Edouard Gerbaud; Maksymilian P Opolski; Nieves Gonzalo; Guillermo J Tearney; Brett Bouma; Aaron D Aguirre; Gary S Mintz; Gregg W Stone; Christos V Bourantas; Lorenz Räber; Sebastiano Gili; Kyoichi Mizuno; Shigeki Kimura; Toshiro Shinke; Myeong-Ki Hong; Yangsoo Jang; Jin Man Cho; Bryan P Yan; Italo Porto; Giampaolo Niccoli; Rocco A Montone; Vikas Thondapu; Michail I Papafaklis; Lampros K Michalis; Harmony Reynolds; Jacqueline Saw; Peter Libby; Giora Weisz; Mario Iannaccone; Tommaso Gori; Konstantinos Toutouzas; Taishi Yonetsu; Yoshiyasu Minami; Masamichi Takano; O Christopher Raffel; Osamu Kurihara; Tsunenari Soeda; Tomoyo Sugiyama; Hyung Oh Kim; Tetsumin Lee; Takumi Higuma; Akihiro Nakajima; Erika Yamamoto; Krzysztof L Bryniarski; Luca Di Vito; Rocco Vergallo; Francesco Fracassi; Michele Russo; Lena M Seegers; Iris McNulty; Sangjoon Park; Marc Feldman; Javier Escaned; Francesco Prati; Eloisa Arbustini; Fausto J Pinto; Ron Waksman; Hector M Garcia-Garcia; Akiko Maehara; Ziad Ali; Aloke V Finn; Renu Virmani; Annapoorna S Kini; Joost Daemen; Teruyoshi Kume; Kiyoshi Hibi; Atsushi Tanaka; Takashi Akasaka; Takashi Kubo; Satoshi Yasuda; Kevin Croce; Juan F Granada; Amir Lerman; Abhiram Prasad; Evelyn Regar; Yoshihiko Saito; Mullasari Ajit Sankardas; Vijayakumar Subban; Neil J Weissman; Yundai Chen; Bo Yu; Stephen J Nicholls; Peter Barlis; Nick E J West; Armin Arbab-Zadeh; Jong Chul Ye; Jouke Dijkstra; Hang Lee; Jagat Narula; Filippo Crea; Sunao Nakamura; Tsunekazu Kakuta; James Fujimoto; Valentin Fuster; Ik-Kyung Jang Journal: Nat Rev Cardiol Date: 2022-04-21 Impact factor: 49.421