Modar Kentar1, Martina Mann2,3, Felix Sahm4, Arturo Olivares-Rivera2, Renan Sanchez-Porras2, Roland Zerelles2, Oliver W Sakowitz2, Andreas W Unterberg2, Edgar Santos2. 1. Department of Neurosurgery, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. modar.kentar@med.uni-heidelberg.de. 2. Department of Neurosurgery, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. 3. Institute of Veterinary Pathology, Center for Clinical Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, Germany. 4. Department of Neuropathology, University Hospital Heidelberg, Heidelberg, Germany.
Abstract
BACKGROUND: The main objective of this study was to generate a hemodynamically stable swine model to detect spreading depolarizations (SDs) using electrocorticography (ECoG) and intrinsic optical signal (IOS) imaging and laser speckle flowmetry (LSF) after a 30-h middle cerebral artery (MCA) occlusion (MCAo) in German Landrace Swine. METHODS: A total of 21 swine were used. The study comprised a training group (group 1, n = 7), a group that underwent bilateral craniectomy and MCAo (group 2, n = 10) and a group used for 2,3,5-triphenyltetrazolium (TTC) staining (group 3, n = 5). RESULTS: In group 2, nine animals that underwent MCAo survived for 30 h, and one animal survived for 12 h. We detected MCA variants with 2 to 4 vessels. In all cases, all of the MCAs were occluded. The intensity changes exhibited by IOS and LSF after clipping were closely correlated and indicated a lower blood volume and reduced blood flow in the middle cerebral artery territory. Using IOS, we detected a mean of 2.37 ± (STD) 2.35 SDs/h. Using ECoG, we detected a mean of 0.29 ± (STD) 0.53 SDs/h. Infarctions were diagnosed using histological analysis. TTC staining in group 3 confirmed that the MCA territory was compromised and that the anterior and posterior cerebral arteries were preserved. CONCLUSIONS: We confirm the reliability of performing live monitoring of cerebral infarctions using our MCAo protocol to detect SDs.
BACKGROUND: The main objective of this study was to generate a hemodynamically stable swine model to detect spreading depolarizations (SDs) using electrocorticography (ECoG) and intrinsic optical signal (IOS) imaging and laser speckle flowmetry (LSF) after a 30-h middle cerebral artery (MCA) occlusion (MCAo) in German Landrace Swine. METHODS: A total of 21 swine were used. The study comprised a training group (group 1, n = 7), a group that underwent bilateral craniectomy and MCAo (group 2, n = 10) and a group used for 2,3,5-triphenyltetrazolium (TTC) staining (group 3, n = 5). RESULTS: In group 2, nine animals that underwent MCAo survived for 30 h, and one animal survived for 12 h. We detected MCA variants with 2 to 4 vessels. In all cases, all of the MCAs were occluded. The intensity changes exhibited by IOS and LSF after clipping were closely correlated and indicated a lower blood volume and reduced blood flow in the middle cerebral artery territory. Using IOS, we detected a mean of 2.37 ± (STD) 2.35 SDs/h. Using ECoG, we detected a mean of 0.29 ± (STD) 0.53 SDs/h. Infarctions were diagnosed using histological analysis. TTC staining in group 3 confirmed that the MCA territory was compromised and that the anterior and posterior cerebral arteries were preserved. CONCLUSIONS: We confirm the reliability of performing live monitoring of cerebral infarctions using our MCAo protocol to detect SDs.
Authors: Marc Melià-Sorolla; Carlos Castaño; Núria DeGregorio-Rocasolano; Luis Rodríguez-Esparragoza; Antoni Dávalos; Octavi Martí-Sistac; Teresa Gasull Journal: Int J Mol Sci Date: 2020-09-08 Impact factor: 5.923