Literature DB >> 31938843

Impact of Clinician Engagement on Implementation of the Pediatric Echocardiography Appropriate Use Criteria.

Markus S Renno1, A Nicole Lambert2, Prince Kannankeril2, David P Johnson3, David A Parra2.   

Abstract

We sought to determine whether awareness of the pediatric appropriate use criteria (AUC) affected transthoracic echocardiogram (TTE) ordering by cardiologists; evaluate for differences in classification of an encounter's AUC clinical scenario by investigator chart review compared with clinicians at the time of the encounter; and assess TTE yield by appropriateness rating. AUC clinical scenario(s) were assigned to patients without prior TTE by investigator chart review of visits in 2014 (n = 209) and 2016 (n = 199), and by clinician classification in 2016 (n = 671). Investigators documented TTE utilization and findings. Between 2014 and 2016, TTE utilization decreased from 54 to 33% (p < 0.001) of "rarely appropriate" (R) encounters, resulting in a decrease in overall TTE utilization from 73 to 55% of encounters (p < 0.001). There was only moderate agreement of AUC appropriateness by investigator chart review and clinician classification (κ = 0.533, p < 0.001). Abnormal TTE findings were detected in 18.7% of R encounters, with 21 of 24 abnormalities in infants younger than 4 months presenting with murmur. A decrease in TTE utilization for R encounters may represent a change in practice from increased awareness of the AUC. AUC scenario classification by clinicians at the time of the encounter could be superior to chart review. TTE abnormalities may be missed in infants younger than 4 months of age when evaluated for murmurs with the AUC.

Entities:  

Keywords:  Appropriate use criteria; Pediatric; Quality improvement; Resource utilization; Transthoracic echocardiography

Mesh:

Year:  2020        PMID: 31938843      PMCID: PMC8182407          DOI: 10.1007/s00246-020-02284-4

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  12 in total

1.  Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001.

Authors:  F L Lucas; Michael A DeLorenzo; Andrea E Siewers; David E Wennberg
Journal:  Circulation       Date:  2006-01-24       Impact factor: 29.690

2.  Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support.

Authors:  Paul A Harris; Robert Taylor; Robert Thielke; Jonathon Payne; Nathaniel Gonzalez; Jose G Conde
Journal:  J Biomed Inform       Date:  2008-09-30       Impact factor: 6.317

3.  Effect of Release of the First Pediatric Appropriate Use Criteria on Transthoracic Echocardiogram Ordering Practice.

Authors:  Ritu Sachdeva; Pamela S Douglas; Michael S Kelleman; Courtney E McCracken; Leo Lopez; Kenan W D Stern; Benjamin W Eidem; Oscar J Benavidez; Rory B Weiner; Elizabeth Welch; Robert M Campbell; Wyman W Lai
Journal:  Am J Cardiol       Date:  2016-08-23       Impact factor: 2.778

4.  Evaluating Appropriate Use of Pediatric Echocardiograms for Chest Pain in Outpatient Clinics.

Authors:  Reid C Chamberlain; Jonathan H Pelletier; Sarah Blanchard; Christoph P Hornik; Kevin D Hill; Michael J Campbell
Journal:  J Am Soc Echocardiogr       Date:  2017-05-10       Impact factor: 5.251

5.  ACC/AAP/AHA/ASE/HRS/SCAI/SCCT/SCMR/SOPE 2014 appropriate use criteria for initial transthoracic echocardiography in outpatient pediatric cardiology: a report of the American College of Cardiology Appropriate Use Criteria Task Force, American Academy of Pediatrics, American Heart Association, American Society of Echocardiography, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Pediatric Echocardiography.

Authors:  Robert M Campbell; Pamela S Douglas; Benjamin W Eidem; Wyman W Lai; Leo Lopez; Ritu Sachdeva
Journal:  J Am Coll Cardiol       Date:  2014-09-29       Impact factor: 24.094

6.  Educational intervention for improving the appropriateness of transthoracic echocardiograms ordered by pediatric cardiologists.

Authors:  Ritu Sachdeva; Pamela S Douglas; Michael S Kelleman; Courtney E McCracken; Leo Lopez; Kenan W D Stern; Benjamin W Eidem; Oscar J Benavidez; Rory B Weiner; Elizabeth Welch; Robert M Campbell; Wyman W Lai
Journal:  Congenit Heart Dis       Date:  2017-02-22       Impact factor: 2.007

7.  Pediatric Appropriate Use Criteria Implementation Project: A Multicenter Outpatient Echocardiography Quality Initiative.

Authors:  Ritu Sachdeva; Joseph Allen; Oscar J Benavidez; Robert M Campbell; Pamela S Douglas; Benjamin W Eidem; Lara Gold; Michael S Kelleman; Leo Lopez; Courtney E McCracken; Kenan W D Stern; Rory B Weiner; Elizabeth Welch; Wyman W Lai
Journal:  J Am Coll Cardiol       Date:  2015-09-08       Impact factor: 24.094

8.  Pediatric Appropriate Use Criteria for Outpatient Echocardiography: Practice Variations among Pediatric Cardiologists, Noncardiologist Subspecialists, and Primary Care Providers.

Authors:  Soultana Kourtidou; Patrick D Evers; Neal W Jorgensen; Richard A Kronmal; Mark B Lewin; Amy H Schultz
Journal:  J Am Soc Echocardiogr       Date:  2017-11-01       Impact factor: 5.251

9.  The Use of Echocardiography for Pediatric Patients Presenting with Syncope.

Authors:  Jonathan H Pelletier; Sarah Blanchard; Reid C Chamberlain; Christoph P Hornik; Michael J Campbell; Kevin D Hill
Journal:  J Pediatr       Date:  2017-09-06       Impact factor: 4.406

10.  Appropriate Use and Clinical Impact of Echocardiographic "Evaluation of Murmur" in Pediatric Patients.

Authors:  Kirsten Rose-Felker; Michael S Kelleman; Robert M Campbell; Matthew E Oster; Ritu Sachdeva
Journal:  Congenit Heart Dis       Date:  2016-06-10       Impact factor: 2.007

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.