Literature DB >> 31933702

Percutaneous closure of an acquired and iatrogenic left ventricular-right atrium communication (Gerbode defect) with an Amplatzer Vascular Plug II.

Roberto Mijangos-Vázquez1, Rogelio Hernández-Reyes1, José R López-Jiménez2.   

Abstract

Gerbode defect is defined as an abnormal left ventricle-right atrium shunting which may have congenital or acquired origin, first described by Thurman in 1838, representing 0.08% of intracardiac shunts and <1% of the congenital heart diseases. The acquired defect can be classified as iatrogenic or non-iatrogenic, with previous cardiac surgery being the most common cause. Gerbode defect is classified depending on its position with respect to the tricuspid valve in supravalvular, infravalvular, or intermediate. Our purpose was to report a rare case of an iatrogenic and acquired Gerbode defect in a 10-year-old male patient following surgical correction of a partial anomalous pulmonary venous return of the right pulmonary veins to the right atrium. The defect was successfully closed percutaneously with an Amplatzer™ Vascular Plug II device. Percutaneous closure of acquired Gerbode defects could be considered as a good option using soft devices to reduce the possibility of severe complications such as complete heart block due to the location of the defect. <Learning objective: Transesophageal echocardiography has a high sensitivity for detection of left ventricle-right atrium shunts; however, it is often difficult to diagnose the anatomic location, relationships of the shunt, and also to distinguish left ventricle-right atrium shunt from sinus of Valsalva rupture, endocardial cushion defect, ventricular septal defect, and tricuspid regurgitation (high flow velocity shunts may also be misinterpreted as pulmonary hypertension). Percutaneous closure of Gerbode defects using soft devices could be considered a good alternative to surgical repair.>.
© 2019 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Amplatzer™ Vascular Plug II; Left ventricle-right atrium shunt; Mexico; Occlusion device; Surgical correction

Year:  2019        PMID: 31933702      PMCID: PMC6951298          DOI: 10.1016/j.jccase.2019.09.008

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


  2 in total

1.  Current outlook after 4 years since the beginning of interventional cardiology in congenital heart disease in Chiapas State

Authors:  Roberto Mijangos-Vázquez; Rogelio Hernández-Reyes
Journal:  Arch Cardiol Mex       Date:  2022-04-04

Review 2.  Gerbode defect or left ventricular to right atrial shunt. Case report and literature review

Authors:  Jesús Sánchez-Pacheco; Eric Rivera-Navarrete; Felipe Santibáñez-Escobar; José A Arias-Godínez; Grecia I Raymundo-Martínez
Journal:  Arch Cardiol Mex       Date:  2022-01-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.