| Literature DB >> 31931606 |
Peishi Jiang1, Juncheng Cui1, Zhiwei Chen1, Zhu Dai1, Yangchun Zhang1, Guoliang Yi1.
Abstract
We established an effective finite element model of knee joint for observation of stress and displacement of meniscus related changes after medial meniscus injury. Different types of medial meniscus injury can lead to varied meniscus stress and displacement changes. Stress and displacement concentration were found in fissure tip of meniscus tear compared to normal meniscus. The posterior horn injury of medial meniscus may initiate combined injury of medial meniscus posterior horn (MMPH) and that of medial meniscus body, and combined injury of MMPH and that of lateral meniscus anterior horn; fissure expansions regarding horizontal fissure, longitudinal fissure and grip-shaped fissure of MMPH were spotted.Entities:
Keywords: Finite element analysis; fracture mechanics; injury model; medial meniscus posterior horn; meniscus
Mesh:
Year: 2020 PMID: 31931606 DOI: 10.1080/10255842.2019.1702167
Source DB: PubMed Journal: Comput Methods Biomech Biomed Engin ISSN: 1025-5842 Impact factor: 1.763