Development of an Ultra High Resolution PET Scanner for Imaging Rodent Paws: PawPET.

Felipe Godinez1, Kuang Gong2, Jian Zhou3, Martin S Judenhofer2, Abhijit J Chaudhari2, Ramsey D Badawi2.   

Abstract

A positron emission tomography (PET) scanner with submillimeter spatial resolution, capable of in vivo imaging of murine extremities was built based on two dual ended readout, hybrid depth of interaction (DOI) PET detectors. Each was composed of a 36 × 36 array of 0.43 mm × 0.43 mm × 8 mm unpolished lutetium oxyorthosilicate crystals separated by a 50 μm white diffuse reflector. The array was coupled to a position-sensing photomultiplier tube at one end and to an avalanche photodiode at the other end. The detector characterization included crystal identification accuracy, DOI, energy, and timing resolution measurements. The scanner was characterized in terms of its spatial resolution and its sensitivity and mouse images were acquired of a mouse paw injected with 18-F-NaF. Out of the 36 × 36 crystals only 33 × 33 crystals were identified. The coincidence timing, DOI, and energy resolution of the scanner was measured to be 2.8 ns, 1.4 mm, and 27%, respectively. The scanner's spatial resolution was measured with a line source and determined from an ordered subsets expectation maximization reconstruction to be 0.56 mm. The sensitivity of the scanner was measured to be 0.6% at the center of the field of view.

Entities:  

Keywords:  Depth of interaction (DOI); high resolution imaging; hybrid DOI detector; mouse paw imaging; positron emission tomography (PET) detectors; preclinical PET

Year:  2017        PMID: 31930184      PMCID: PMC6953759          DOI: 10.1109/TRPMS.2017.2765486

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  2 in total

1.  Experimental validation of a rodent PET scanner prototype based on a single LYSO crystal tube.

Authors:  Marta Freire; Andrea Gonzalez-Montoro; Gabriel Cañizares; Ahmadreza Rezaei; Johan Nuyts; Stuart S Berr; Mark B Williams; Jose M Benlloch; Antonio J Gonzalez
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-11-01

2.  Performance evaluation of the mouse version of the LabPET II PET scanner.

Authors:  Émilie Gaudin; Christian Thibaudeau; Louis Arpin; Jean-Daniel Leroux; Maxime Toussaint; Jean-Francois Beaudoin; Jules Cadorette; Maxime Paillé; Catherine M Pepin; Konin Koua; Jonathan Bouchard; Nicolas Viscogliosi; Caroline Paulin; Réjean Fontaine; Roger Lecomte
Journal:  Phys Med Biol       Date:  2021-03-09       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.