Literature DB >> 31928217

Evaluation of ciliary body by ultrasound bio-microscopy after trans-scleral diode cyclo-photocoagulation in refractory glaucoma.

Abdallah Mohsen Mohamed Safwat1, Laila Mohammed Hammouda1, Hosam Ibrahim El-Zembely1, Ismail Ahmed Nagib Omar1.   

Abstract

PURPOSE: To evaluate the morphological changes of the ciliary body after diode laser trans-scleral cyclo-photocoagulation using ultrasound bio-microscopy in refractory glaucoma. SETTINGS: This prospective, interventional, non-comparative, non-randomized, longitudinal study was performed on 40 eyes with refractory glaucoma, during the period between February 2016 and March 2018.
METHODS: All patients were treated with single session diode laser trans-scleral cyclo-photocoagulation. The intraocular pressure was obtained over a period of 3 months after the operation and morphological changes of the ciliary body were observed using ultrasound bio-microscopy.
RESULTS: Trans-scleral cyclo-photocoagulation has achieved a reasonable success in reducing intraocular pressure to less than 22 mm Hg without increasing the number of glaucoma medication. The overall success rate was 40%, as the intraocular pressure decreased from a baseline mean value of 54.70 ± 12.27 to 42.45 ± 9.85 mm Hg 1 week after operation, 33.50 ± 8.00 mm Hg after 1 month, and 25.60 ± 6.62 after 3 months of operation. Ultrasound bio-microscopy detected reduction in the length and width of ciliary processes in addition to the ciliary muscle thickness of the treated quadrants. Intraocular pressure was more correlated to the width of the ciliary processes.
CONCLUSION: Trans-scleral cyclo-photocoagulation is a rapid and effective procedure in treatment of refractory glaucoma with intraocular pressure reduction. Ultrasound bio-microscopy is a promising twin tool for cyclo-destructive procedures to detect ciliary body changes and can be used as a guide for re-treatment procedures.

Entities:  

Keywords:  Diode cyclo-ablation; ciliary body; refractory glaucoma; ultrasound bio-microscopy

Mesh:

Year:  2020        PMID: 31928217     DOI: 10.1177/1120672119899904

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Repeatability and Reliability of Quantified Ultrasound Biomicroscopy Image Analysis of the Ciliary Body at the Pars Plicata.

Authors:  Joy Li; Jennifer Drechsler; Anna Lin; Matthew Widlus; Azam Qureshi; Gianna Stoleru; Osamah Saeedi; M Roni Levin; Mona Kaleem; Mohamad Jaafar; William P Madigan; Janet Leath Alexander
Journal:  Ultrasound Med Biol       Date:  2021-04-13       Impact factor: 3.694

2.  Deep Learning Segmentation, Visualization, and Automated 3D Assessment of Ciliary Body in 3D Ultrasound Biomicroscopy Images.

Authors:  Ahmed Tahseen Minhaz; Duriye Damla Sevgi; Sunwoo Kwak; Alvin Kim; Hao Wu; Richard W Helms; Mahdi Bayat; David L Wilson; Faruk H Orge
Journal:  Transl Vis Sci Technol       Date:  2022-10-03       Impact factor: 3.048

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.