Literature DB >> 31926867

Comparison of bone thickness in infrazygomatic crest area at various miniscrew insertion angles in Dravidian population - A cone beam computed tomography study.

Arathi Murugesan1, Arvind Sivakumar2.   

Abstract

INTRODUCTION: Infrazygomatic crest miniscrews are an important advancement in the field of orthodontics for anchorage reinforcement. The size of the miniscrews and the site of placement depend on the bone thickness in the infazygomatic crest area. The bone morphology and the thickness vary among different ethnicities of population.
OBJECTIVES: To assess the bone thickness in the infrazygomatic crest area around the distobuccal root of the maxillary first molar using cone beam computed tomography and determine the best possible site and angulation for the placement of the miniscrew. Therefore, to determine the size of the implant that will suit the Dravidian population.
METHODS: The infrazygomatic crest bone thickness was evaluated on 10 patients using cone beam computed tomography. The measurements were made along the distobuccal root of maxillary first molar at different angulations ranging from 75° to 40° to the occlusal surface of the molar.
RESULTS: The infrazygomatic crest bone thickness was of 4.5mm to 9mm for the Dravidian population, when measured at an angle of 40° to 75° to the maxillary first molar occlusal plane and of 11 to 17mm above the occlusal plane. Student t-test (confidence interval 95%) was done to determine gender variation and compare the bone thickness of right and left side. ANOVA and post-hoc test were done to find the statistical difference between the bone thickness measured at different insertion angles.
CONCLUSIONS: The best possible site for miniscrew insertion is 12 to 17mm above the occlusal plane at an angle of 65° to 70°, with no injury to the adjacent anatomical structures, no mucosal irritation and adequate stability for the miniscrew. The ideal infrazygomatic crest screw length for Dravidian population is 9 to 11mm.
Copyright © 2019 CEO. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Bone thickness; Cone beam computed tomography; Crête infrazygomatique; Infrazygomatic crest; Mini-vis; Miniscrew; Tomographie à faisceaux coniques assistée par ordinateur; Épaisseur osseuse

Mesh:

Year:  2020        PMID: 31926867     DOI: 10.1016/j.ortho.2019.12.001

Source DB:  PubMed          Journal:  Int Orthod        ISSN: 1761-7727


  4 in total

1.  Evaluation of mandibular buccal shelf characteristics in the Colombian population: A cone-beam computed tomography study.

Authors:  Natalia Escobar-Correa; Maria Antonia Ramírez-Bustamante; Luis Alejandro Sánchez-Uribe; Juan Carlos Upegui-Zea; Patricia Vergara-Villarreal; Diana Milena Ramírez-Ossa
Journal:  Korean J Orthod       Date:  2021-01-25       Impact factor: 1.372

2.  Miniscrew insertion sites of infrazygomatic crest and mandibular buccal shelf in different vertical craniofacial patterns: A cone-beam computed tomography study.

Authors:  Murilo Matias; Carlos Flores-Mir; Márcio Rodrigues de Almeida; Bruno da Silva Vieira; Karina Maria Salvatore de Freitas; Daniela Calabrese Nunes; Marcos Cezar Ferreira; Weber Ursi
Journal:  Korean J Orthod       Date:  2021-11-25       Impact factor: 1.372

3.  Clinical effectiveness of orthodontic miniscrew implantation guided by a novel cone beam CT image-based computer aided design and computer aided manufacturing (CAD-CAM) template.

Authors:  Lingling Qiu; Hui Xu; Pingping Feng; Xiaoyan Sha; Hongwei Zhang
Journal:  Ann Transl Med       Date:  2021-06

4.  Anatomical consideration for optimal position of orthodontic miniscrews in the maxilla: a CBCT appraisal.

Authors:  Maha S Al Amri; Hanadi M Sabban; Doaa H Alsaggaf; Fahad F Alsulaimani; Ghassan A Al-Turki; Mohammad S Al-Zahrani; Khalid H Zawawi
Journal:  Ann Saudi Med       Date:  2020-08-06       Impact factor: 1.526

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.